Connect, Inc.
Host Connection Setup
February 1998
2-21
Driver Test (SDLC only)
Use this option to test the SDLC host link adapter driver software. This test is
useful to ensure that the SDLC driver is functioning internally with the server
software.
Caution
Do not run the driver test on a live system. Doing so disconnects
any active users because the active SDLC link needs to be brought
down during this test.
SDLC Driver Software Check
Are you sure you want to shutdown the SDLC network (y/n)?
Figure 2-15 Driver Check SDLC shutdown screen
After shutting down the SDLC connection, the following tests and results are
displayed for a properly operating adapter.
Starting dlpitst at Thu Sep 26 16:49:50 1996
Test 1 Connection established: lpa 1 bind 1 pid 8556
Data test 1 lasted 7 seconds.
Test 1 sent 1000 msgs 128000 bytes for 142 msgs per second or 146285 baud.
Test 1 rcvd 1000 msgs 128000 bytes for 142 msgs per second or 146285 baud.
Starting dlpitst at Thu Sep 26 16:49:57 1996
Test 1 Connection established: lpa 1 bind 1 pid 8557
Data test 1 lasted 6 seconds.
Test 1 sent 1000 msgs 1000 bytes for 166 msgs per second or 1333 baud.
Test 1 rcvd 1000 msgs 1000 bytes for 166 msgs per second or 1333 baud.
receive-errs xmt-errs
UPA CDI_State Frames-out Frames-in wd mf af crc ovr abt und abt
--- ------------- ---------- ---------- -- -- -- ---- ---- ---- ---- ----
1 INPUT_ALLOWED 6994 6994 0 0 0 0 0 0 0 0
Deactivating SNA test server
Press ENTER to continue
Figure 2-16 Driver Check Screen