Specifications
13
Xtreme/104 Opto User's Manual, ver. 0.00
Specifications
Operating Environment
Storage
temperature:
-65
°
C to 150
°
C
Operating
temperature:
0
°
C to 70
°
C (standard version)
-40
°
C to 85
°
C (industrial version)
Humidity: 0 to 90% relative humidity, non-condensing
Power Requirements
Xtreme-2/104 Opto; Xtreme-4/104 Opto
+5 VDC +/-5% @ 260 mA (typical)
PC Bus Interface
PC interrupts are jumper selectable, (3, 4, 5, 6, 7, 9, 10, 11,
12, 14, 15)
Base address for I/O ports is jumper selectable, requires 8
addresses
One PC/104 expansion connector
Communications
UARTs
16C2850 dual UARTs communication controllers
On chip 128 byte TxD and RxD FIFO buffers per port
Automatic RTS/CTS (Hardware) flow control
Automatic XON/XOFF (Software) flow control
Compatible with 16550 style software drivers
RS-232
Programmable baud rate generator - up to 230.4.8K baud on
all RS-232 ports
Full duplex, point to point
RS-485/422
Programmable baud rate generator - up to 460.8K baud on all
RS-485/422 ports
Full duplex, point to point or multi-drop
Half duplex, point to point or multi-drop
Jumper selectable RxD and TxD line termination resistors
Compatible with RS-422
Control Signals
RS-232
TxD; RxD; RTS; CTS
RS-485/422 RTS
±
; TxD
±
; CTS
±
; RxD
±
Summary of Contents for Xtreme 104 Opto