904568 Rev A CONMED ClearView™ Smoke Evacuation System Operator’s Manual 

Page 8

•  Refer routine servicing to qualified biomedical technical personnel. 

•  Changes or modifications not expressly approved by CONMED could void the user’s  

  authority to operate the equipment. 

The warranty on this product is void if any of these warnings are disregarded. 

1.4.2    CAUTIONS:

•  Federal law (United States of America) restricts this device to be used by, or on the order of a    

physician. 

 

•  Do not block either the tubing or the filter. If either becomes occluded or significantly    

 

restricted, the motor/blower may overheat and cause the unit to fail.

•  Using any other filter or accessory not supplied by CONMED may cause damage and/

    or cause the system to be inoperable and may void the warranty.

•  Care must be exercised in the installation of hoses, adapters and suction canisters.  Failure to 

    follow the procedures outlined in this manual may result in overheating of the motor and may 

    void the unit warranty.

•  This device is not intended for evacuation of fluid.  If fluid is expected to be aspirated to the 

    ClearView™ Filter, fluid collection devices must be installed with the vacuum hose assembly.  

Failure to install a fluid collection device could cause filter blockage and electrical damage. 

•  The Filter should be changed according to the life of the filter.  The Filter, used with the 

ClearView™ Smoke Evacuation System(s), should not be used for more the time specified for 

each filter. Failure to change the filter may result in decreased efficiency and contamination of 

the electric motor, vacuum pump, and sound absorbing media within the unit.

•  Do not block either the tubing or the filter during operation. An occlusion or significant 

restriction may cause the motor to overheat and the unit to stop working. 

•  The installation of this equipment must be performed such that the intake and exhaust vents

    located on the bottom of the system are not obstructed. Failure to properly install the unit may

    cause reduced performance, damage and/or cause the system to be inoperable and may void

    the warranty.

•  The ambient temperature during operation must be kept between 50°F to 104°F (10°C to 

    40°C)

•  The relative humidity during operation must be kept between 10% to 75%. 

•  An atmospheric pressure range of 700 hPA to 1,060 hPa.

Summary of Contents for ClearView 60-8585-120

Page 1: ...ClearView Smoke Evacuation System Operator s Manual...

Page 2: ...A The revision level of this manual is specified by the highest revision letter found on either the inside front cover or enclosed errata pages if any Manual Number 904568 REVA Unit Serial Number ____...

Page 3: ...ions and Warnings 2 0 OPERATING INSTRUCTIONS 10 2 1 System Controls 2 2 Filter Instructions 2 3 Set up and Operation 2 4 Specifications 3 0 MAINTENANCE 21 3 1 General Maintenance Information 3 2 Clean...

Page 4: ...ion Air filter whose high tech patented U S Patent 5874052 design captures particulates and micro organisms from 1 to 2 microns at an efficiency of 99 999 The third stage filtration uses the highest g...

Page 5: ...VAC 50 60 Hz 220 240 VAC 50 60 Hz 2 Type of protection against electrical shock UL 60601 1 Clause 5 1 Class I 3 Degree of protection against electric shock UL 60601 1 Clause 5 2 Type CF Applied Part...

Page 6: ...cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the inte...

Page 7: ...ult The CONMED filters and single use accessories are completely disposable Please dispose of according to your local codes or regulations and hospital policy These filters may be disposed of or incin...

Page 8: ...uid If fluid is expected to be aspirated to the ClearView Filter fluid collection devices must be installed with the vacuum hose assembly Failure to install a fluid collection device could cause filte...

Page 9: ...nvironmental ambient temperature 14 F to140 F 10 C to 60 C Storage environmental relative humidity 10 to 75 There are no user serviceable components in the ClearView Smoke Evacuation System s Refer se...

Page 10: ...QUALIFIED SERVICE PERSONNEL DANGER CAUTION RISK OF EXPLOSION IF USED IN THE PRESENCE OF FLAMMABLE ANESTHETICS WARNING CAUTION TYPE CF APPLIED PART IPX1 PROTECTION AGAINST INGRESS OF WATER AS DETAILED...

Page 11: ...g the suction ON membrane switch to illuminate yellow STANDBY LED Turn the system main power off O by unplugging the power cord from the appliance inlet on the unit or the receptacle in the wall SUCTI...

Page 12: ...ystem is turned on the filter life indicator with light up the leftmost GREEN LED indicating 100 filter life The indicator will progress thru subsequent GREEN LEDs to an AMBER LED as time elapses and...

Page 13: ...ice is not intended for evacuation of fluid If fluid is expected to be aspirated using the Filter or the CONMED ClearView Smoke Evacuation System fluid collection devices must be installed with the va...

Page 14: ...2015 All rights reserved 904568 Rev A CONMED ClearView Smoke Evacuation System Operator s Manual Page 14 Figure 1 Unit Control Panel...

Page 15: ...mensions H x W x D inches 6 x 11 x 15 5 Dimensions H x W x D centimeters 15 2 x 27 9 x 39 4 Weight lbs 4 3 Noise Level dBA nominal 55 0 dBA Footswitch Pneumatic Standard Automatic Control Activation Y...

Page 16: ...it is used in such an environment Emissions Test Compliance Electromagnetic Environment Guidance RF Emissions CISPR 11 Group 1 The ClearView uses RF energy only for its internal function Therefore it...

Page 17: ...hat of a typical commercial or hospital environment Surge IEC 61000 4 5 1 kV differential mode 2 kV common mode 1 kV differential mode 2 kV common mode Mains power quality should be that of a typical...

Page 18: ...meters m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey should be less than the compliance level in each frequency range Interference may occur in the vici...

Page 19: ...equipment Rated maximum output power of transmitter W Separation distance according to frequency of transmitter m 150 kHz to 80 MHz 3 5 d P v1 80 kHz to 800 MHz 3 5 d P v1 800 kHz to 2 5 GHz 3 5 d P...

Page 20: ...oper mating cleanliness and absence of damage to the filter inlet Obvious external or internal damage to the system 3 4 Troubleshooting the System see below Maintenance Section 3 0 PROBLEM POTENTIAL C...

Page 21: ...ClearView Smoke Evacuation System use it to properly return your unit If you do not have the original packing material ask Customer Service for advice on how to pack the unit for return shipment Step...

Page 22: ...NMED by purchaser for the specific system giving rise to the liability Purchaser agrees to indemnify and hold CONMED harmless from and against all liabilities claims and demands of third parties of an...

Page 23: ...matters involving the validity interpretation and application of this agreement shall be controlled by the laws of the State of New York Using any filter not offered by CONMED may cause damage to the...

Page 24: ...e Evacuation System Operator s Manual Page 24 Distributed by ConMed Corporation 525 French Road Utica NY 13502 USA 1 800 448 6506 U S Only or 1 315 797 8375 International www conmed com Manufactured b...

Reviews: