Conlan Wiegand CT 1200 Family Manual Download Page 1

 

 

460110

  

CT 1200 

Keypad for Wiegand installations:  
Format 26/8/4 
26 bits for whole code. 8/4 bits for each digit. Set up 
on site by short cut wires and power up.  
External controlling of the LED´s and the buzzer. 
IP 67, 12 VDC 
2,5 m cable 8 cores 
Works together with the Conlan 5000 Wiegand 
controller for up to 512 users. 

 

 

 

460111 

 

PR 1200 

Prox Reader for Wiegand Installations:  
Format 26 bits 
External controlling of the LED´s and the buzzer. 
IP 67, 12 VDC 
2,5 m cable 8 cores 
The reader can be delivered in a smaller unit.   

 

Works together with the Conlan 5000 Wiegand 
controller for up to 512 users.

 

 

 

  

 

       

 

 

 

460194 BioTag Office 

Fingerprint reader for Wiegand installations:  
Format 26 bits 
Stand Alone. 
External controlling of the LED´s and the buzzer. 
2,5 m cable, 12 cores, IP 67, 12 VDC 
Works together with the Conlan 5000 Wiegand 
controller for up to 512 users.

 

 

 

 

460116  Wiegand Con  Controller 5000 for Wiegand installations. 26 bits: 

For 1 door. In and out Reader. Door contact. REX 
contact. Relays (2 pcs) for door and alarm. Output for 
LED/Buzzer in Readers. 232 communication to PC and 
485 for networking. Log in the controller for 3500 logs. 
Incl  Windows 

quick

 setup program. Stand alone 

programming of cards/transponders or by computer. 
Enrolling, deleting all cards, mastercard, single cards, 
missed cards etc.    

 

 

  

Art. No. Short name  Description

 

 

Art. No. Short name  Description

 

 

Art. No. Short name  Description

 

 

Art. No. Short name  Description

 

 

Wiegandv.2 Man. ENGjun12

 

Wiegand 

CT 1200 Family 

Summary of Contents for Wiegand CT 1200 Family

Page 1: ...reader for Wiegand installations Format 26 bits Stand Alone External controlling of the LED s and the buzzer 2 5 m cable 12 cores IP 67 12 VDC Works together with the Conlan 5000 Wiegand controller for up to 512 users 460116 Wiegand Con Controller 5000 for Wiegand installations 26 bits For 1 door In and out Reader Door contact REX contact Relays 2 pcs for door and alarm Output for LED Buzzer in Re...

Page 2: ...e by jumper software Door contact input NC Request to exit input REX NC Inputs for two 26bit Wiegand readers In and Out Open collector outputs for reader LED and Buzzer Stand Alone Reset using wire Box tamper contact NC 12Vcc 500mA max power input Connections Caution read all the instruction in order to assure a proper working of controller Connector description 12V GND Power supply 12Vcc 500mA ma...

Page 3: ...s forced open then alarm relay will be still active for AT time after closing the door Same if door is left open Invalid card status time ICT is the time for readers to show the invalid status of a card using LED s and buzzer Re Lock Door if active the door is re locked when is closed or opened depending of the following setting Re Lock on opening is valid only if the previous setting is active If...

Page 4: ...mportant to know user position in database With system on Delete a lost damage card present the card with position number lower then card we want to delete For instance if we want to delete card in position 37 we will present card in position 36 If we do not have card in position 36 36 is free we will present card in position 35 And so on In other words this phase can be delete first card enrolled...