Advanced options in the PR 1000 Proximity Reader: 

 

Generally it is the installer who is setting up the parameters/programming of the proximity reader. 

 

Reset the PR 1000 

 

Make a short cut between the yellow and the brown core. Connect the power. Remove the short cut. Now the proximity reader is back in 

factory default. No MT, CT or TR is active. All is reset. Yellow LED is flashing. The first TR shown will be the MT. The next TR shown 

will be CT. PR 1000 is now ready for programming the User Transponder (transponders up 1000 pcs). 

 

Set up by the Control Transponder (CT): 

 

CT can be used in configuration to the MT and all parameters can be set up as the following: 

 

Configuration of the Proximity Reader: 

 

 

Description 

Indication* 

Action 

Indication 

Action 

Programming 

New value 

Ø O O 

CT1 

-- Ø Ø 

MT 

Buzzer on/off, repeat 

On = Ø, Off = O 

-- Ø Ø 

CT2 

-- -- -- 

MT 

Shift Locked Indication 1-8, 

repeat MT to choose 

– 8, see the LED 

indication 1 

– 8 

-- -- -- 

CT3 

-- -- -- 

MT 

Shift Unlocked Indication 1-8, 

repeat MT to choose 

– 8, see the LED 

indication 1 

– 8 

-- -- -- 

CT4 

-- Ø O 

MT 

Not in function for PR 1000 

 

-- Ø O 

CT5 

-- Ø Ø 

MT 

Toggle open collector 2 polarity 

’—’: 

Ø = invert, 0 = not invert 

-- Ø Ø 

CT6 

-- O Ø 

MT 

Not in function for PR 1000 

 

-- O Ø 

CT7 

-- Ø Ø 

MT 

Set open collector output time 

Time between CT7 and MT is 

impulse time. 0 = toggle 

-- Ø ø 

CT8 

ؠؠؠ

MT 

Save and exit 

All the chosen parameters will be 

saved and in function. 

ø ø ø 

CT9 

 

 

Exit without save, same as time up 

 

 

*: Explanation to the indications: LED indication: 

(default: Yellow for locked, yellow and green for unlock). 

 

Indication 

Yellow LED 

Green LED 

Red LED 

Ø O O 

On 

Off 

Off 

-- Ø Ø 

Different 

On 

On 

-- Ø O 

Different 

Flash 

Off 

ؠؠؠ

Flash 

Flash 

Flash 

 

Examples for some settings: 

 

Save new set up: CT8 - MT. 

Leave programming without saving: Wait for time up. LED goes back to normal lighting. 

 

Examples: 

UT = User Transponder. UT1 = User Transponder 1 etc. 

 

Example 1: 

MT1, UT1, UT2, UT3: 3 User Transponders are now programmed (for impulse). Placed in position 1 to 3. 

 

Exaples 2: 

MT1, UT1, UT2, MT2, UT3, UT4: 2 User Transponders are now programmed (for impulse) and 2 for toggle. 

 

Example 3: 

MT1, MT2, MT3, UT3: User Transponder 3 is deleted. 

 

Example 4: 

CT2, MT3: LED lighting for normal use is now changed to no. 

3

 (as shown on the proximity reader) CT4, CT5, CT6, CT7, CT8 and MT - 

then the setup is saved in the reader. 

 

Specifications: 

Voltage: 

+ 9 

– 15 V DC, 100 mA. 

Output (yellow core): 

max. 500 mA. 

Extern controlling buzzer and red LED 
Extern controlling buzzer, 

Hold

 and lock 

Operating temperature: 

-30° C til + 80° C. 

Humidity: 

100%, IP67. 

Color: 

Black, optional white. 

Dimensions (H x W x D): 

130 x 50 x 8 mm. 

Cable: 

2,5 m, 8 core. 

 
 
 