Introduction
PR 1000 is a flexible proximity reader for a lot of application: At normal work the yellow LED is lit (the left one).Activation by a confirmed
transponder/card, the yellow and the green LED are lighting for the activation time. If not confirmed... the red LED is
lighting shortly. There is a buzzer integrated also for indication, either confirmed/not confirmed transponder/card
(2 different sounds). Additional the buzzer can be activated directly by GND on the brown wire.
The transponders/cards (TR) are stored in positions from 1 to 1000. At delivery all positions
are empty. The first TR shown after power up will be the Master Transponder (MT).
The next shown will be Control Transponder (CT). Now the proximity reader is for
programming(see page 3 for reset the PR 1000) User Transponder (UT).
Transponder(cards for PR 1000
Position:
Transponder:
Name:
Position:
Transponder:
Name:
00
MT
22
0
CT
23
1
UT 1
24
2
UT 2
3
UT 3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
1000
Programming the Transponder/cards (TR) im
pulse:
Show MT 1 time (yellow LED is flashing) (the proximity reader is now in programming mode), show a new TR, will be confirmed by
sound and flashing. Show the next etc. - there is space for 1000 TR. All TR will be stored from position 1 and the following numbers up.
The time up for programming mode is approx. 10 seconds after every programming. The programmed transponder will activate the
output for approx. 5 seconds (impulse).
Programming the Transponder (TR)
toggle:
Show MT 2 times after each other (MT2) (green LED flashing). Show a new TR, will be confirmed by sound and lighting. The TR
programmed will activate the output as a toggle. The positions can be mixed up for either input/toggle TR's. All TR will be programmed
on the first free space in the positions.
Delete TR:
Show MT 3 times (red LED flashing). Show the TR/TR's you wish to delete. That/those positions are now free..
Delete a TR not present:
Show MT 4 times (green and red LED flashing). Show the transponder programmed just before that TR you want to delete e.g.: TR 12
has to be deleted. MT 4 times - show TR from position 11 and TR 12 is now deleted. Position 12 is now free e.g. 2: Delete TR 13 - MT 4
times - show TR from position 11 etc. NB: All new programmed TR will be stored on the first free space.
Delete TR on position 1:
Show MT 5 times (all LED flashing). TR on position 1 is now deleted.
Installing your new PR 1000 Proximity Reader:
Wire color
Inst - Prox
Function
Description
Red
+12 V DC
Supply, 9
– 15 V / 100 mA
Black
0 V, GND
Supply
Yellow
Open collector output, 500 mA.
0V active
Output for door opening, relay, alarm etc.
Green/white
Sabotage loop
Short cut in the reader
Brown
0V active buzzer/
Hold
Extern controlling/Hold function
Orange
0V active red LED
Extern controlling
Blue
0 V active, for
REX
button.
REX-time as for pulse.
Output for door opening, relay, alarm etc.