background image

9. Connection examples

Direct connection

Relay connection

Thank you for choosing Conlan’s products.

For technical support, call: +45 72 40 62 32

+12V DC

0V DC

REX, 0V active

High Security/external buzzer, 0V active

External controlling green LED, 0V active

External controlling red LED, 0V active

 

CT 2000 Prox

ALARM SYSTEM A/S

 

 

Prox

1

3

5

7

9

2

4

6

8
0

0V GND

Doorstrike

+ 12V DC

+ 12V DC

0V GND

Doorstrike

+ 12V DC

+ 12V DC

+12V DC

0V DC

REX, 0V active

Hight Security/external buzzer, 0V active

Relay

External controlling green LED, 0V active

External controlling red LED, 0V active

 

CT 2000 Prox

ALARM SYSTEM A/S

 

 

Prox

1

3

5

7

9

2

4

6

8
0

NO

NC

C

Relay

0V GND

Doorstrike

+ 12V DC

+ 12V DC

0V

+ 12V DC

Summary of Contents for 480000

Page 1: ...Codetastatur C1000 Mykey Art Nr 480000 sort 480001 hvid Classic Art Nr 482000 sort 482001 hvid User manual C1000_usermanual_ENGjan20...

Page 2: ...iguration of C1000 4 1 Service code 4 2 Configuration overview 4 3 Change the Master code 4 4 Change the Service code 4 5 LED Indications 4 6 Outputs 4 7 Special settings 5 Blocking 6 Manual reset 7 T...

Page 3: ...Service code 2 Installation Mount the reader on a even surface use the following drill template for precise fit ting Connect the wires to power supply door strike assembly board etc Colour scheme Red...

Page 4: ...utput 1 and 2 191 200 Reserved for special functions 3 2 Programming user codes The Master code is used to program change delete the users By default the Master code is 4711 LED indication No light Li...

Page 5: ...oggles the output Ie the code is entered to unlock the door and entered to lock it again Programming the same user 3 times By programming the same code on the same position 3 times the output is desig...

Page 6: ...s Key in a position and it counts automatically to the next position Codes can be programmed alternatively as you see fit For more codes tags repeat from here Note This programming mode overwrites exi...

Page 7: ...00 goes back to the previous point and the next setting can be made The navigation is by entering the position value followed by 4 2 Configuration overview Position Setting Factory default 00 Master c...

Page 8: ...normal adjust the LED s for correct code tag indication active adjust the keying indication how the LED will react while keying To adjust the LED s press on the following yellow LED toggle by press gr...

Page 9: ...nds is the value automatically 0 which corresonds to set the output as toggle bonding the positions and output 1 bonding the positions and output 2 Both outputs are bonded to specific positions By fac...

Page 10: ...codes and Mifare tags only activate output 2 High Security High Security increases the C1000 s security by ensuring 2 positions have to be activat ed before the output is activated the positions must...

Page 11: ...lights and the buzzer sounds Turn the voltage off and disconnect the yellow and brown wire The C1000 is now reset to factory default and the user codes tags are deleted 7 Technical specifications Volt...

Page 12: ...ED 0V active External controlling red LED 0V active CT 2000 Prox ALARM SYSTEM A S Prox 1 3 5 7 9 2 4 6 8 0 0V GND Doorstrike 12V DC 12V DC 0V GND Doorstrike 12V DC 12V DC 12V DC 0V DC REX 0V active Hi...

Reviews: