5.1.4
PWR_OK Signal
With the PWR_OK signal on the feature connector (X35), the user can control the SBC's start-up process. When this signal is set to low, the SBC
is kept in reset until the PWR_OK signal is asserted. When the signal is asserted (set to high), it indicates to the SBC that the supplied power is
stable. The SBC then begins its onboard power-up sequence.
5.1.5
Power Status LEDs
The conga-IA5 provides two LED signals ( and P_LED-) on pins 2 and 4 of the front panel connector X39. The signals indicate the
different power states of the conga-IA5.
Table 16 Power Status LEDs Description
LED State
Description
ACPI State
Off
Power-off
S5
Steady Green
Running
S0
Steady Yellow
Sleeping
S3
5.1.6
CR2032 Cell Battery Holder
The conga-IA5 provides a CR2032 cell battery (for commercial variants) or a BR2330A cell battery (for industrail variants) placed inside a battery
holder (M37). The battery supplies power to maintain the CMOS settings and configuration data in the UEFI flash chip.
Warning
Danger of explosion if battery is incorrectly replaced. Replace only with same or equivalent type recommended by the manufacturer. Dispose
of used batteries according to the manufacturer’s instructions.
Table 17 Single-Color Power LED
LED State
Description
ACPI State
Off
Sleeping or power-off (not running)
S3, S5
Steady Green
Running
S0
M37
P
ANASONIC
+
3V
CR2032