INSTALLATION
Calibration
To achieve a starting position for the degree of
purification based specifically on your water, the
water purifier must be calibrated (reset).
Calibration may only be performed if:
•
The water purifier is new and has never
been used before.
•
The incoming water quality changes for
some reason, such as moving the water
purifier.
•
Membrane replacement has recently
been carried out.
Do not drink or use the water that is
produced during the calibration
procedure!
To calibrate the water purifier:
1.
With tap installed:
Open the purified
water tap. Within 10 seconds (with the tap
still open), you must press the calibration
button, see fig. H, and then hold it
depressed until the lights for purification
levels I and II come on and then go out.
When only the On/Off light is lit, the
button can be released.
1.
Without tap connected:
After the third
automatic flushing in the flushing
procedure, which takes 30 seconds, the
water purifier stops for a second and then
starts producing purified water to the
reject water outlet. Once the production of
purified water has started, the calibration
button must be pressed within 10
seconds, see fig. H, and then kept
depressed until the lights for purification
levels I and II come on and then go out.
When only the On/Off light is lit, the
button can be released.
If any of the lights for purification levels I-
III does not go out, go through the
Checkpoints under “Flushing” again and
restart calibration.
2. Allow the water purifier to produce purified
water for at least 10 minutes. The lights
for purification levels I and II flash once.
The current water quality level is
displayed by the lamp for level III starting
to shine continuously, indicating the
maximum degree of purity.
3. If a wandering flashing light appears
between the lights for levels I - III, the
calibration has been carried out
incorrectly. In this case, repeat the
calibration from the beginning.
4.
With tap installed:
Close the purified
water tap and allow the water purifier to
flush automatically. Allow the flushing to
stop.
4.
Without tap installed:
Pull out the plug,
wait for one minute and then reconnect it.
The water purifier flushes. Pull out the
plug after the automatic flushing. Connect
the purified water hose to the peripheral
equipment.
The water purifier is now ready to produce
purified water.
H
Moving the water purifier
If you move the purifier from one place to another,
you should remember the following points:
•
Close the shut-off valve for the feed
water.
•
Pull out the plug.
•
Always transport the appliance upright.
•
Installation takes place according to the
installation instructions.
•
New calibration should only be performed
if the quality of the feed water has
changed, or if the membrane has been
replaced.
The appliance must be put in storage if
it is not going to be used for a period
of more than 4 months, see the section
“Storage”.