background image

14

Table of contents

EG Konformitätserklärung | EC Certificate of Conformity 

Page  3

DE FLOW Tauchpumpe 30 

Page  4+

GB FLOW Submersible pump 30 

Page  13

1. 

Safety 

Page 15

1.1 

Identification of hints in the operating instructions 

Page  15

1.2 

Carry out work in a safety conscious manner 

Page  16

1.3 

Unilateral modification and spare parts manufacturing 

Page  17

1.4   Unproven usage 

Page  17

2.  

Scope of delivery 

Page  17

3.  

Application 

Page  17

4.  

Technical data 

Page  18

5.  

Transport  

Page  19

6.  

Electrical connection 

Page  19

7.  

Set-up/installation 

Page  19

8.  

Commissioning 

Page  20

9.  

Maintenance 

Page  20

10.   Appendix 

Page  21

GC-P-FLOW-30-12-1101-JH1.indd   14

25.01.12   14:04

Summary of Contents for FLOW Series

Page 1: ...FLOW Tauchpumpe 30 Betriebsanleitung Submersible pump 30 Operating instructions GC P FLOW 30 12 1101 JH1 indd 1 02 03 15 14 03 KBN FLOWTP30 OS KBN FLOWTP30...

Page 2: ...gigen grundlegenden Sicherheits und Gesundheitsanforde rungen der EG Richtlinien entsprechen 2006 95 EC 2004 108 EC to which this certi cate applies conforms to the basic health and safety requiremen...

Page 3: ...s Arbeiten Seite 5 1 3 Eigenm chtiger Umbau und Ersatzteilherstellung Seite 6 1 4 Unzul ssige Betriebsweisen Seite 6 2 Lieferumfang Seite 6 3 Einsatz Seite 6 4 Technische Daten Seite 7 5 Transport Sei...

Page 4: ...Betriebsanleitung enthaltenen Sicherheitshinweise die bei Nichtbe achtung Gef hrdungen f r Personen hervorrufen k nnen sind mit einem allgemei nen Gefahrensymbol Sicherheitszeichen nach DIN 4844 W 9...

Page 5: ...ten des VDE und der rtlichen Energieversorgungsunter nehmen Sicherheitshinweise f r Wartungs Inspektions und Montagearbeiten Der Betreiber hat daf r zu sorgen dass alle Wartungs Inspektions und Monta...

Page 6: ...m Kabel mit Schutzkontaktstecker ange bautem Schwimmerschalter Druckabgang mit Innengewinde 1 sowie 1 mit Au engewinde 3 Einsatz Tauchpumpen der Baureihe FLOW Tauchpumpe 30 sind zur F rderung von Klar...

Page 7: ...Drehzahl 2900 min 1 Motorschutz Temperaturw chter in Wicklung eingebaut Stecker Schutzkontaktstecker Schutzart IP 68 Isolationsklasse Motor B Ausl stemperatur Motorschutz 120 C Maximale Eintauchtiefe...

Page 8: ...en Betrieb von Pumpen der Schutzklasse I gilt nach IEC 335 2 41 1984 nderung 1 1990 Pumpen der Schutzklasse I die zur Verwendung in Schwimm becken Gartenteichen bestimmt sind m ssen mit einer Fehlerst...

Page 9: ...Halter einklemmen sodass der Schwimmschalter nach oben zeigt siehe Seite 10 Abbildung 2 Pumpe schaltet sich nicht selbst ndig aus und ist deshalb vor Trockenlauf zu sch tzen 8 Inbetriebnahme 9 Wartung...

Page 10: ...nnlinie nach ISO 9906 18 199 mm 141 mm 30 mm G1 G1 357 mm Abbildung 1 Abbildung 2 FLOWTP30 mit arretiertem Schwimmerschalter f r Schaltanlagenbetrieb Schaltanlagenbetrieb Kann auf Wunsch bei Schaltanl...

Page 11: ...11 Anhang 199 mm 141 mm 30 mm G1 G1 357 mm Abbildung 3 Darstellung mit Adapter G 1 AG GC P FLOW 30 12 1101 JH1 indd 11 25 01 12 14 04...

Page 12: ...12 GC P FLOW 30 12 1101 JH1 indd 12 25 01 12 14 04...

Page 13: ...FLOW Submersible pump 30 Operating instructions 13 GC P FLOW 30 12 1101 JH1 indd 13 02 03 15 14 04 KBN FLOWTP30 OS KBN FLOWTP30...

Page 14: ...e 15 1 2 Carry out work in a safety conscious manner Page 16 1 3 Unilateral modification and spare parts manufacturing Page 17 1 4 Unproven usage Page 17 2 Scope of delivery Page 17 3 Application Page...

Page 15: ...gulations it is also essential that the special safety instructions given under other headings be observed 1 1 Identification of hints in the operating instructions Safety instructions given in this o...

Page 16: ...t be observed Safety Regulations for the Owner Operator All dangers due to electricity must be avoided for details consult the regulations of your local Electricity Supply Company Safety Regulations f...

Page 17: ...y for plugging in with 10 m cable with 6FKXNo plug built in adjustable oat switch 1 pressure outlet with female thread and 1 pressure outlet with male thread 3 Application FLOW submersible pump 30 ser...

Page 18: ...wer P1 0 8 kW Speed 2900 rpm Motor protection Temperature monitor built into winding Plug Schuko plug Protection class IP 68 Motor insulation class B Motor protection activation temperature 120 C Maxi...

Page 19: ...rotection class I the following applies according to IEC 335 2 41 1984 Amendment 1 1990 Pumps of protection class I intended for use in swimming pools or garden ponds must be equipped with a residual...

Page 20: ...pwards see page 21 figure 2 The pump does not cut out and must be automatically protected from running dry 8 Commissioning The automatic level control of the FLOWTP30 pump switches on when the set cut...

Page 21: ...ge volume Curve to ISO 9906 Figure 1 199 mm 141 mm 30 mm G1 G1 357 mm Figure 2 FLOWTP30 with locked float switch control panel always on operation Control panel always on Float switch mounting for alw...

Page 22: ...22 Appendix 199 mm 141 mm 30 mm G1 G1 357 mm Figure 3 Illustration with G 1 male thread adapter GC P FLOW 30 12 1101 JH1 indd 22 25 01 12 14 04...

Page 23: ...Bild Ma und Ausf hrungsangaben entsprechen dem Tag der Drucklegung nderungen die dem technischen Fortschritt und der Weiterentwicklung dienen behalten wir uns vor Modell und Produktanspr che k nnen ni...

Page 24: ...drohre FLEX Isolierungen K lte W rme Solar FLAM Brandschutz Abschottung Manschetten Tape Kitt M rtel CLIC Befestigungs und Montagesysteme Rohrschellen Montageschienen CLEAR Wasseraufbereitung Filtrati...