43
Status display:
The status display shows the remaining capacity, e.g.:
You can switch to the flow display with the
q
and
p
keys, e.g.:
6.3
MENU FUNCTIONS
Pressing the key
opens the first menu level:
Use the
key to switch to the next menu item and confirm with <OK>:
· Raw water hardness
The raw water hardness is measured with hardness measuring instruments and (see chapter 12 “ACCES-
SORIES”) then entered as follows:
/
Select “RAW HARD” with the
key and then confirm with <OK>.
/
The display shows the default value of 20 °dH.
/
Set the raw water hardness using the
and
keys and then save with <OK>.
Adjustment range: 1 to 99 °dH
Step size: 1 °dH
The value is saved as the default value and subsequently shown on the status display.
· Bottle type
/
Select “TYPE” with the
key and then confirm with <OK>.
/
The display shows the default value of PURE 7.5.
/
Set the bottle type with the
or
key and then save with <OK>.
Selectable bottle types: PURE 7.5, SOFT 16.8, PURE 25.0, SOFT 60.0
Once the bottle type has been saved, the status display shows the capacity of the new bottle in litres.
· Data
The “DATA” section shows the total fill volume in litres since commissioning and the total number of con-
sumed bottles by type.
· Reset
Selecting “RESET” and confirming with <OK> will reset the remaining bottle capacity to zero.
The display will show “0 LITRE” and an acoustic signal will be heard.
/
Press <OK> again and set the bottle type using the
or
keys and then save with <OK>.
Once the bottle type has been saved, the status display shows the capacity of the new bottle in litres.
250 L
300 L/h