FAULTS
Help with faults:
The opening of the units and the replacement of the water pressure charged parts
may only be effected by authorized personal in order the ensure the unit security
and its tightness.
Fault
Cause
Remedy
Water flow rate falls.
Screen is blocked.
Replace the screen!
Leaks in the cartridge filter with
pressure reducer.
Inform the fitter or nearest cus-
tomer service centre!
Filter bowl becomes turbid.
Cartridge filter with pressure re-
ducer has been exposed to high
temperatures or solvents.
Inform the fitter or nearest cus-
tomer service centre!
Hairline cracks on the filter bowl.
Cartridge filter with pressure re-
ducer has been exposed to high
temperatures or solvents.
Inform the fitter or nearest cus-
tomer service centre!
Downstream pressure slowly ris-
es when no water flowing.
Impermissible increase in pres-
sure due to service water heating.
Check the safety valve of the hot
water boiler!
Inform the fitter or nearest cus-
tomer service centre!
Downstream pressure slowly ris-
es when no water flowing.
Wear in the pressure reducer car-
tridge.
Check the safety valve of the hot
water boiler!
Inform the fitter or nearest cus-
tomer service centre!