QuickBridge Wiring Diagram Manual
9
QB3 BRIDGE RECEIVER WIRING
QB3 Bridge Receiver Wiring
250
(14) COM 3
(15) SOUTH 1S
(16) NORTH 1S
(18) COM 4
(28) COM 5
(29) SW A
(19) R1
(20) R2
(22) R3
(23) R4
(25) AUX 1
(26) AUX 2
(30) SW B
(5) COM 1
(6) UP 1S
(10) COM 2
(11) EAST 1S
(12) WEST 1S
(1) AC-1 (OR DC +)
(2) AC-2 (OR DC -)
(3) MAIN-IN
(4) MAIN-OUT
(14) COM 3
(15) SOUTH 1S
(16) NORTH 1S
(18) COM 4
(28) COM 5
(29) SW A
(19) R1
(20) R2
(22) R3
(23) R4
(25) AUX 1
(26) AUX 2
(30) SW B
(5) COM 1
(6) UP 1S
(10) COM 2
(11) EAST 1S
(12) WEST 1S
(8) DOWN 1S
(1) AC-1 (OR DC +)
(2) AC-2 (OR DC -)
(3) MAIN-IN
(4) MAIN-OUT
Output to South bridge 1-speed function
Output to North bridge 1-speed function
Not used
110VAC (or 12-24VDC+)
AC Neutral (or 12-24VDC -)
Not used
Not used
Not used
Not used
Not used
Not used
Not used
K3 Bridge Receiver wiring
Not used
Not used
Not used
Not used
Not used
Not used
Not used
110VAC (or 12-24VDC+)
AC Neutral (or 12-24VDC -)
Output to Up 1-speed function
Output to East 1-speed function
Output to West 1-speed function
Not used
Output to Down 1-speed function
Input from SW A
Not used
Not used
Input from SW A (if trolley present on hoist)
Input from SW A (if functions needed)
Output to function
Output to function
Output to function
Output to function
Not used
Not used
Signal input needed to run function
Signal input needed to run function
Not used
K3 Hoist "A" Receiver wiring
Output to Com1 (and Com2 if trolley present on hoist)
Output of MAIN-IN input voltage (if not needed, cap off)
Output of MAIN-IN input voltage (if not needed, cap off)
110VAC (or voltage needed for Mainline contactor on MAIN-OUT)
110VAC (or voltage needed for Mainline contactor on MAIN-OUT)
QB3 RADIO WIRING
(8) DOWN 1S
Not used
(14) COM 3
(15) SOUTH 1S
(16) NORTH 1S
(18) COM 4
(28) COM 5
(29) SW A
(19) R1
(20) R2
(22) R3
(23) R4
(25) AUX 1
(26) AUX 2
(30) SW B
(5) COM 1
(6) UP 1S
(10) COM 2
(11) EAST 1S
(12) WEST 1S
(8) DOWN 1S
(1) AC-1 (OR DC +)
(2) AC-2 (OR DC -)
(3) MAIN-IN
(4) MAIN-OUT
110VAC (or 12-24VDC+)
AC Neutral (or 12-24VDC -)
Output to Up 1-speed function
Not used
Output to Down 1-speed function
Input from SW B
Not used
Not used
Input from SW B (if trolley present on hoist)
Input from SW B (if functions needed)
Output to function
Output to function
Output to function
Output to function
Not used
Not used
Signal input needed to run function
Not used
Output to East 1-speed function
Output to West 1-speed function
K3 Hoist "B" Receiver wiring
Output to Com1 (and Com2 if trolley present on hoist)
Output of MAIN-IN input voltage (if not needed, cap off)
110VAC (or voltage needed for Mainline contactor on MAIN-OUT)
RELEASED
XA-574435
CAD SYSTEM: SOLIDWORKS
11/07/2016
D SAMPSON
K COCHRAN
11/07/2016
70051
ER APPR:
ER DATE:
ER ENGR:
ER NO.
STATUS:
11/07/2016
This drawing and the information shown constitute trade secret and confidential property
of Conductix, Inc. It is subject to recall, and is loaned for use only in connection with the
authorized manufacture or installation of Conductix, Inc. products, and on the condition
that it will be treated as confidential and will not be disclosed, published or reproduced in
whole or in part, or permitted to be viewed or used by any other party, without specific
written permission. Receipt and use of the drawing and information constitutes
acceptance and agreement to the above.
MINIMUM
MACHINED
SURFACE
0
10102 F Street
Omaha, NE 68127
800-521-4888
WEIGHT(REF): 0.00 LB
MAT'L: Material <not specified>
PROPRIETARY AND CONFIDENTIAL
UNLESS OTHERWISE SPECIFIED
INTERPRET GEOMETRIC TOLERANCING
PER: ASME Y14.5
PRIMARY UNITS ARE IN
INCH POUND SECONDS
SECONDARY UNITS IN
MILLIMETERS KILOGRAMS SECONDS
TOLERANCES ARE AS FOLLOWS
DECIMAL=
X.X 0.1 IN [2,5 MM]
X.XX 0.03 IN [0,8 MM]
X.XXX 0.010 [0,25 MM]
ANG. 1
FRAC. 1/16
THREAD CLASS: 2
ALL DIMENSIONS GREATER THAN 24.00 INCHES HAVE A
TOLERANCE OF .063 IN UNLESS OTHERWISE SPECIFIED
DRAWN:
APPR:
DESCRIPTION:
SIZE
B
MATERIAL NO. 2:
REV
SCALE:
1:4
K COCHRAN
D SAMPSON
SHEET
3
OF
6
RADIO SCHEMATICS FOR QUICK BRIDGE