background image

BRIDGEGUARD PLUS

TM

 MANUAL

5

SECTION 1 - SAFETY

1.0 Safety Information Responsibility

1.0.1  All owner, operator, and maintenance personnel must read and understand all manuals associated with this product before 

installation, operation, or maintenance.

1.0.2  The manual provides information on the recommended installation, operation, and maintenance of this product. Failure to read and 

follow the information provided could cause harm to yourself or others and/or cause product damage. No one should install, operate, 
or attempt maintenance of this product prior to familiarizing themselves with the information in this manual.

1.1 Safety Messages

The following safety messages are used in this manual to alert you to specific and important safety related information.

 

CAUTION

CAUTION

 indicates unsafe actions or situations that have the potential to cause injury, and/or minor equipment or property damage.

 DANGER 

DANGER

 indicates hazards that have the potential to cause severe personal injury or death.

 WARNING

WARNING

 indicates unsafe actions or situations that have the potential to cause severe injury, death, and/or major equipment or property 

damage.

NOTE

NOTE

 is used to alert you to installation, operation, programming, or maintenance information that is important, but not hazard related.

1.2 Limitation of Liability

1.2.1  All data and information in this mounting instructions have been compiled in compliance with the applicable standards and 

regulations, best practice and our many years of experience and knowledge. 

1.2.2 The manufacturer accepts no liability for damages resulting from: 

•  Failure to comply with this document 
•  Improper use 
•  Use by untrained personnel
•  Unauthorized modifications
•  Technical changes
•  Use of unauthorized replacement parts and accessories
•   The actual scope of delivery may differ from the explanations and descriptions provided here if the model in question is a special 

one, if additional equipped has been ordered or due to recent technical changes.

1.2.3  The obligations agreed upon in the delivery agreement and our General Terms and Conditions of business apply, as do the delivery 

conditions of the manufacturer and the legal regulations applicable at the time the contract was concluded. 

1.2.4 All products are subject to technical modifications in the context of improvement of function and further development.

Summary of Contents for BridgeGuard Plus

Page 1: ...BRIDGEGUARD PLUSTM MANUAL XA 579411 3 08 24 22 BridgeGuard PlusTM Installation Operation Maintenance Manual...

Page 2: ...se once Buyer returns such goods FOB point of original shipment by Seller at the risk and cost of Buyer Goods replaced by Seller shall become the property of Seller There is no guarantee or warranty a...

Page 3: ...pfler has the unique ability to offer a degree of service not found anywhere else Conductix Wamp er s team of highly quali ed service technicians and engineers have years of experience servicing our c...

Page 4: ...Equipment 7 SECTION 2 PRODUCT DISPOSAL 8 2 0 Product Disposal Recycling 8 SECTION 3 OVERVIEW 9 11 3 0 General Product Overview 9 3 1 Specifications 9 3 2 Structure 10 3 3 Status Indicator Lights 10 3...

Page 5: ...tial to cause severe injury death and or major equipment or property damage NOTE NOTE is used to alert you to installation operation programming or maintenance information that is important but not ha...

Page 6: ...of performing assigned tasks and independently identifying and avoiding potential hazards based on their specialist training knowledge and experience as well as their knowledge of the applicable regul...

Page 7: ...ork clothing Primarily for protection against entrapment by moving machine parts Work clothing must be close fitting with a low resistance to tearing it must have close fitting sleeves and no protrudi...

Page 8: ...rn and disposal agreement disassembled components must be recycled as follows All metallic parts must be sorted and recycled by material type All plastic components must be sorted and recycled by mate...

Page 9: ...inition Distance Measurement Technology Precise time of flight measurement Visible Laser Red Light IP 67 rated for indoor and outdoor use 100 240 V AC voltage supply Switching Output Relay Relay outpu...

Page 10: ...tus Q1 Q2 3 Zero Level 7 LED Status Indicator 4 Mounting Hole M4 8 Control Elements 3 3 Status Indicator Lights 3 3 1 The sensor box for BridgeGuard Plus features status indicator LEDs that provide in...

Page 11: ...2 Push and hold SELECT button for 3 4 seconds to enter TEACH MODE The top LED Q1 NEAR will light up 3 Push the SELECT button two more times so the Q1 NEAR and Q1 FAR LEDs are both lit 4 Push the SET...

Page 12: ...r to I Beam web 4 0 1 Mount reflector to the I Beam using appropriate hardware See Figure 4 1 NOTE A spacer must be used between the I Beam s web and the reflector back plates A lock washer much be us...

Page 13: ...Figure 7 2 WARNING Maximum sensor trigger distance should be no more than 115 feet NOTE The sensor can be mounted to the flange of the beam or other alternative surfaces Figure 4 2 4 5 6 3 1 2 Figure...

Page 14: ...SECTION 4 INSTALLATION 4 2 Sensor Targeting 4 2 1 Included below is a general sensor target installation your specific installation may vary See Figure 4 4 Figure 4 4 End of Runway End of Runway Refl...

Page 15: ...See Table 4 1 Terminal Wire Color Description 4 Brown 24VDC 5 7 Blue 24VDC 8 Black Q1 PNP Out 9 White Q2 PNP Out 10 Gray Teach Input Table 4 1 L 120V BLACK 18AWG 6 N 120V WHITE 18 AWG 6 PE GREEN 18AW...

Page 16: ...4 5 3 Setting up SLOWDOWN distance detection 1 With the sensor mounted to the crane move crane to the SLOWDOWN distance point 2 Press and hold it will take approximately 5 seconds the SELECT pushbutt...

Page 17: ...Electrical Maintenance WARNING Equipment damage due to improper cleaning Never use cleaning agents containing aggressive substance Never use pointed objects for cleaning Interval Maintenance Work To b...

Page 18: ...sors and to the control box Unable to read output signals Electric Connection Inspect the connection to terminal blocks in control box and to the sensor Laser is not on reflector plate Realign sensor...

Page 19: ...BRIDGEGUARD PLUSTM MANUAL 19 NOTES...

Page 20: ...urlington ON L7L 0E6 Customer Support Phone 1 800 667 2487 Phone 1 450 565 9900 Fax 1 450 951 8591 info ca conductix com M XICO Calle Trevi o 983 C Zona Centro Apodaca NL M xico 66600 Customer Support...

Reviews: