Performing the calibration check
3. Position the device as near as possible to the wall at the height of point A1.
4. Turn the device through 180° and mark point A3. The difference between 
points A1 and A3 is the tolerance.

When A1 and A3 are more than 3 mm/10 m apart, an adjustment is necessary. 
Contact your authorised dealer or else CONDTROL Service Department.

Checking the vertical line

Position the device about 5 m from a wall. Fix a plumb bob with a line of 2.5 m 
length on the wall, making sure that the bob can swing freely. Switch on the 
device and align the vertical laser to the plumb line. The precision is within 
the specified tolerance if the deviation between the laser line and the plumb 
line is not greater than ± 1.5 mm.

TECHNICAL DATA

Parameter

Value

Self-leveling range              

± 4°

Precision                        

± 3 mm /10 m

Operating range (depending on room 
illumination)       

 20 m

Laser wavelength                         

635 nm/ < 1 mW

Power supply / operating time         

3x1.5V LR6(AA) / 30 hours

Operating temperature              

0°C ... +50°C

Storage temperature              

-10°C ... +70°C

Dimensions (W x H x D)      

110х68х97 mm

Weight (incl. battery)          

0,32 kg

PACKAGE

Level, batteries, target, laser viewing glasses, bag, belt, adapter 5/8’’ to 1/4’’.

OPERATION

Preparing the calibration check

It is possible for you to check the calibration of the laser. To do this, position 
the device midway between 2 walls, which must be at least 5 meters apart. 
Do this by turning the unit on, thus releasing the transport restraint (cross 
laser on). See Section «Horizontal and vertical leveling» about this.
1. Mark point A1 on the wall.
2. Turn the device through 180° and mark point A2. You now have
a horizontal reference between points A1 and A2.

3

Summary of Contents for MicroX

Page 1: ...umenti ru instrument izmeritelnyj niveliry lazernye_urovni condtrol lazernyi_nivelir_c ondtrol_microx http www vseinstrumenti ru instrument izmeritelnyj niveliry lazernye_urovni condtrol lazernyi_nive...

Page 2: ......

Page 3: ...3 CONDTROL MicroX MicroX CONDTROL 635 3 10 100...

Page 4: ...4 5 CONDTROL MicroX CONDTROL MicroX 2 36 1 2 3 4 5 8 5 6 7 8 3 5 2 4 2 5 2 5 1 2 3 5 4 8 6 7...

Page 5: ...6 7 CONDTROL MicroX CONDTROL MicroX 5 10 20 2 5 1 A1 2 180 A2 3 10 20 A2 4 180 A3 A1 A3 A1 A3 3 10 4 0 3 10 20 635 1 2x1 5 AA 30 0 32 0 C 50 C 10 C 70 C W x H x D 110 68 97 0 32 5 8 1 4 2 3...

Page 6: ...8 9 CONDTROL MicroX CONDTROL MicroX 5 2 5 1 5 5 2 5 2...

Page 7: ...wing glasses as safety goggles The laser viewing glasses are used for improved visualization of the laser beam but they do not protect against laser radiation Do not use the laser viewing glasses as s...

Page 8: ...one The Out Of Level function must be activated in order to do horizontal and vertical leveling It is activated by releasing the transport restraint The Out Of Level function signals when the device i...

Page 9: ...on between the laser line and the plumb line is not greater than 1 5 mm TECHNICAL DATA Parameter Value Self leveling range 4 Precision 3 mm 10 m Operating range depending on room illumination 20 m Las...

Page 10: ...device about 5 m from a wall and switch on the cross laser Mark point B on the wall Turn the laser cross approx 2 5 m to the right and mark point C Check whether the horizontal line from point C is l...

Page 11: ...es The calibration expenses after repair are paid separately We do not bear responsibility for 1 The loss of profits and inconvenience connected with a defect of the instrument 2 The expenses on the a...

Page 12: ......

Reviews: