Performing the calibration check
3. Position the device as near as possible to the wall at the height of point A1.
4. Turn the device through 180° and mark point A3. The difference between
points A1 and A3 is the tolerance.
When A1 and A3 are more than 3 mm/10 m apart, an adjustment is necessary.
Contact your authorised dealer or else CONDTROL Service Department.
Checking the vertical line
Position the device about 5 m from a wall. Fix a plumb bob with a line of 2.5 m
length on the wall, making sure that the bob can swing freely. Switch on the
device and align the vertical laser to the plumb line. The precision is within
the specified tolerance if the deviation between the laser line and the plumb
line is not greater than ± 1.5 mm.
TECHNICAL DATA
Parameter
Value
Self-leveling range
± 4°
Precision
± 3 mm /10 m
Operating range (depending on room
illumination)
20 m
Laser wavelength
635 nm/ < 1 mW
Power supply / operating time
3x1.5V LR6(AA) / 30 hours
Operating temperature
0°C ... +50°C
Storage temperature
-10°C ... +70°C
Dimensions (W x H x D)
110х68х97 mm
Weight (incl. battery)
0,32 kg
PACKAGE
Level, batteries, target, laser viewing glasses, bag, belt, adapter 5/8’’ to 1/4’’.
OPERATION
Preparing the calibration check
It is possible for you to check the calibration of the laser. To do this, position
the device midway between 2 walls, which must be at least 5 meters apart.
Do this by turning the unit on, thus releasing the transport restraint (cross
laser on). See Section «Horizontal and vertical leveling» about this.
1. Mark point A1 on the wall.
2. Turn the device through 180° and mark point A2. You now have
a horizontal reference between points A1 and A2.