HAVELLS SYLVANIA EUROPE LTD
Avis Way Newhaven East Sussex BN9 0ED
www.havells-sylvania.com
MI/1469-C - 11
a
edition - 04/2012
installation and maintenance sheet
aluna SP/100
Features - meaning of the symbols shown on the label:
underwater model for submerged operation only minimal voltage halogen lamp
100W max - 12V - 8.35A - GY6.35 axial filament
totally dust-proof
IP68 10m indefinite submerged operation - max allowed depth 10m
mounting on normally inflammable surfaces allowed
very low voltage feeding with security transformer
Class III
no earth required
replace the damaged protective glass
getting rid of as urban waste forbidden
separate collection is mandatory
when the product is at the end of its life
glass features: plane float glass - safety tempered
Installation:
• lamp feeding shall be by means of a security transformer (symbol ), power not
less than 100VA, output voltage 12V. The transformer shall be protected against
overloading and short-circuit (see models single CT box (4068479) - double CT
box (4068480)). The feeding cable must be neoprene rubber type H07RN8-F
(EN 60598-2-18 CENELEC HD 22.4), of minimum section 2x1.5mm
2
. The
floodlight is supplied by us with the lamp already installed and connected with
H07RN8-F cable of section 2x2.5mm
2
in length 5.5 meters. The cable and the
fixture must not be tampered with for any reason.
• Check carefully that the transformer power is sufficient.
• max. installation depth 10m.
Relamping:
• respect fully type and power of lamp as shown on the label.
Read carefully the instructions of the lamp manufacturer for proper
lamp use. The relamping must be done with maximum attention
avoiding to dirty the sealing gasket and its contact to surface. It is therefore
necessary before opening the fixture to carefully wipe the floodlight
then unscrew the round frame by the proper key (code 4068469).
If the gasket is damaged, deformed or not in perfect conditions
it is necessary to change it with the one enclosed in the packing.
(see figure)
Maintenance:
• it is essential to do a frequent cleaning of the glass and
of the outer surface of the fixture to avoid build up of mud and dirtiness resulting
in dangerous overheating due to obscured light and heat dissipation. Clean the
glass screen carefully by removing limestone deposits by means of a scraper.
N.B. the floodlight must be operated underwater.
Quality control: Should you have any complaint please get in touch with our
company or its sales organization. Please give the number of your order as well
as the serial number that recognizes the fixture.
119
60
75
¯106
¯140
200
90
It is necessary to place the gasket exactly
into its seat as shown in the picture.
Then screw on gently the frame and tighten
it by the opening/closing key (4068469).
ET/0932
NB: These assembly instructions must be given to end users for correct maintenance and so that they know how to change the lamp. The
appliance must not be tampered with or transformed and it must be installed and used as supplied and in compliance with the National
Rules on Installations. Any non-compliant installations will invalidate all forms of guarantee. The company cannot be held responsible for
damage caused by incorrect assembly.
IS13104