Follow the installation instructions:
1. Mark the minimum required assembly height on the wall behind the
hotplate (650 mm for electric, and 700 mm for gas hotplates, Fig. 3).
2. Mark the position of the center of the hotplate with a vertical line.
3. Drill the holes, fix the wall holder (F) at the required height using the
supplied wall plugs (G) and screws (H) (1,010 mm for electric and 1,060 mm
for gas hotplates, Fig. 4).
4. Hang the body of the unit on the holder (A). Set the exact vertical position
with screws (J) and (I), Fig. 4.
5. For the airing mode, mount the backflow valve on the output hole, and
connect the output hole of the fan to the hole in the wall using a flexible
pipe. If necessary, use the adapter (150/120 mm).
Note:
Flexible pipe and diameter adapter are not supplied.
6. Mount both chimney covers on the body of the unit (C, D). Shift the upper
chimney cover (D) up to the required height, and mark the height of the
hole for the wall holder of the upper cover (Fig. 5). Remove both chimney
covers.
7. Drill the holes at this height, and fix the wall holder of the upper chimney
cover on the wall plugs (K) using screws (L), see Fig. 6).
8. Mount and screw the lower and upper chimney covers (C, D).
9. Plug the supply cable in the wall outlet.
UNIT INSTALLATION
•
Only authorized personnel can install the power connection!
• Only the customer is responsible for installation in situ. Defects caused by incorrect installation are not covered
by the warranty.
• Remove all the covering and marketing materials from the unit before the first use.
• We recommend that you let a specialized company perform the installation.
• The manufacturer bears no responsibility for damage caused to people, animals or objects as a result of incorrect
installation.
Fig. 3
Fig. 4
Fig. 5