92
EN
IDV4260wh
Connection of the terminal box of the appliance
•
The hob is already supplied with a mains cable. In case it is necessary to replace the mains cable due to damage,
Fig. 11 or Fig. 12, shows the wiring of the terminal box.
•
The mains cable must be replaced with the same type of cable with the corresponding wire cross section.
•
After connecting the new mains cable to the terminal box, secure the cable from being pulled out from the
terminal box.
•
Follow the same procedure as described above when installing the appliance into the worktop cut-out and
connecting it to the mains power.
Connecting the hob by a 3-core mains cable (230 V)
Use a cable with wires of a diameter of at least 4 mm
2
.
Connecting the hob by a 4-core mains cable (400 V)
Use a cable with wires of a diameter of at least 2.5 mm
2
.
GREEN/YELLOW
BROWN
BLUE
GREEN/YELLOW
BLACK
BROWN
BLUE
Fig. 11
Fig. 12