62
EN
IDV2060, 5460, 5560
•
Use a grounded electric power supply only.
• Do not use adapter plugs, connectors or extension cables. They could imply a risk of fire from overheating.
• The supply cable plug or the circuit breaker has to be freely accessible even after the installation of the unit.
• Electrical safety of the unit can only be guaranteed if the protective terminal of the unit is connected with the
protective conductor of the mains.
• The manufacturer bears no responsibility for damages caused to people or things as a result of a missing or bad
protective connection.
• The power cord must be located so that it does not come into contact with hot parts of the unit and so that it is
not deformed and excessively bent.
Connection of the terminal box of the unit
WARNING!
Only a qualified expert can perform connection of the unit.
A switch or circuit breaker for disconnection of the unit from the mains must be installed in the wiring before
the unit, where the distance between open contacts of all poles is at least 3 mm.
The unit can be connected in the following two ways:
a) by a 3-core supply cable (230 V)
Use a cable with wires of a diameter of at least 4 mm, e.g. the H05V2V2-F3x4.0 type, and press endings on its
ends to prevent fraying. The connection of IDV 2060 is in Fig. 5a, the connection of IDV 5460 and IDV 5560
is in Fig. 5b.
b) by a 4-core or 5-core supply cable (400 V 2N)
Use e.g. a cable with wires of a diameter of at least 4 mm, e.g. the H05V2V2-F4x4.0 or H05V2V2-F5x4.0 type, and
press endings on its ends to prevent fraying. The connection of IDV 2060 is in Fig. 6a, the connection of IDV
5460 and IDV 5560 is in Fig. 6b.
230 V ~, H05V2V2-F3x4,0
Fig. 5a
230 V ~, H05V2V2-F3x4,0
Fig. 5b