Specifications
Model
kW
Volts
Phase
Amps
Minimum Breaker Size
Wire Size (Amps)
CEB-3
3
240
1
12.5
20
16
CEB-5
5
240
1
20.8
30
24
CEB-6
6
240
1
25.0
40
32
CEB-8
8
240
1
33.3
50
40
CEB-9
9
240
1
37.5
50
40
CEB-10
10
240
1
41.7
60
48
CEB-12
12
240
1
50.0
70
56
CEB-15
15
240
1
62.5
100
80
CEB-18
18
240
1
75.0
100
80
CEB-19
19
240
1
79.2
100
80
CEB-20
20
240
1
83.3
125
100
CEB-23
23
240
1
95.8
125
100
CEB-24
24
240
1
100.0
125
100
CEB-25
25
240
1
104.2
150
120
CEB-28
28
240
1
116.7
150
120
CEB-208-9
9
208
3
25.0
40
32
CEB-208-11
11.25
208
3
31.2
40
32
CEB-208-15
14.7
208
3
40.8
60
48
CEB-208-22
22.5
208
3
62.5
100
80
CEB-208-30
29.4
208
3
81.6
125
100
CEB-600-9
9
600
3
8.7
15
12
CEB-600-15
14.7
600
3
14.1
20
16
CEB-600-18
18
600
4
17.3
30
24
CEB-600-24
23.7
600
5
22.8
30
24
CEB-600-30
29.4
600
3
28.3
40
32
Control Voltage 24 Volts AC
Tank Capacity – Approx. 2 Gallons
Shipping Weight – about 85 pounds
Inlet and Outlet pipe size 1 1/4” NPT
Pump Switch Rating, 120 Volt, 1 HP
Maximum Recommended Operating Temperature 180º F
Floor heating temperatures are generally 90º F to 110º F
Minimum Recommended Operating Pressure 12 PSI
Warning: The control transformer is sized to power only the internal
controls. External devices must be powered from a separate power source.
4