background image

Revision 1.21

     October 2007.

1

CONCEPT

CONCEPT

CONCEPT

CONCEPT

CONCEPT

Small Low Profile Powered Enclosure.

P/N: 995200PE

INSTALLATION MANUAL

Overview

The Small Low Profile Powered Enclosure can be used wherever Battery-backed 12V supplies are required to power Concept
Modules and associated devices such as Detectors, Readers and Auxiliary Devices such as Strobes, Sounders, Locks, etc.

The Box is designed to house the Transformer, Power Supply PCB, 7AH Battery and a single B1, B2 or C size Concept Module.
e.g.  1 Door/2 Door Access Module, Mini Expander, Analogue Module or LAN Isolator.  The Power Supply features a high
reliability design that offers unconditional stability, and has been designed and tested for compatibility with Proximity readers.

When used with a 2 Door Access Module or Mini Expander, a single Ribbon cable may be used (P/No: 605050 or 605049) to
connect the Power Supply to the Module.  When this option is used with the Mini Expander, Zones 7 and 8 are connected to the
AC Fail and Low Battery alarm outputs of the Power Supply and cannot be used as general purpose Zone Inputs.

Electrical Specifications

Input:

16V AC @ 2.5A.

Output Voltage:

13.8V DC +/-2%, up to 2A.

(From Transformer provided)

Maximum Output Current:

2 Amps.

Switching Frequency:

50 kHz. approx.

Output Ripple:

100mV RMS max. @ Iout = 2A.

Conversion Efficiency:

80%. approx.

Load Regulation:

+/- 100mV @ Iout = 0.1A to 2.0A.

“Low Battery” trigger voltage: 11V DC.

Battery capacity:

12V 7AH Sealed Lead Acid.

Mechanical Specifications

Dimensions:

Length:  252  mm.  (Allow 20mm at bottom of case for Mains cable entry)
Width:  358 mm.

Depth:  83 mm.

Weight:

7.2 kg.  (Includes mains transformer, battery and cover)

Power Supply PCB dimensions:

95mm X 80mm X 50mm high.

Operating  Environment:

0º to 40º Celsius (Ambient)

15% to 85% Relative humidity (non-condensing)

Powered Equipment Box Parts List

- 2A Power Supply PCB assembly and Mains Transformer mounted in Metal enclosure.
- PCB Mounting plate.

-

Installation Manual.  (This document)

- Installation Kit containing:

-

2 x 2 Way Plug on Screw Terminals.

-

Battery connection cable.  (P/No: 605051)

-

1 x 8 Way Plug on Screw Terminal.

-

1 x 4A Fast Blow fuse.  (Spare)

-

Tamper Switch and Metal bracket.

-

1 x 1.0 Amp Slow Blow Mains fuse.  (Spare)

-

2 x 6.3mm Tamper switch connectors.

-

15 x PCB Mounting Clips. *

-

1 x 10 way Ribbon cable -20cm.  (P/No: 605050) *

-

15 x M3 screws. *

NOTES: 1) *  These items not included in installation kit if this product is supplied with a Concept Module already fitted.

2) If the enclosure and Battery are to be installed in any way other than that shown in Diagram 3 on Page 3, the

optional Battery retaining bracket (P/No: 926005) is required.

Designed & manufactured in Australia.

Due to on-going product development this manual is subject to change without notice.

©    2004 - 2005.  Inner Range Pty. Ltd.

Part No:  635200PE

Summary of Contents for 995200PE

Page 1: ...e 100mV RMS max Iout 2A Conversion Efficiency 80 approx Load Regulation 100mV Iout 0 1A to 2 0A Low Battery trigger voltage 11V DC Battery capacity 12V 7AH Sealed Lead Acid Mechanical Specifications Dimensions Length 252 mm Allow 20mm at bottom of case for Mains cable entry Width 358 mm Depth 83 mm Weight 7 2 kg Includes mains transformer battery and cover Power Supply PCB dimensions 95mm X 80mm X...

Page 2: ...e Diagram 3 on the following page 1 Installation environment should be maintained at 0º to 40º Celsius and 15 to 85 Relative humidity non condensing 2 The enclosure must be secured to a flat vertical surface using fasteners through the four keyhole mounting holes in the chassis We recommend mounting the enclosure with the Mains Cable entry and Transformer at the bottom as shown in Diagram 3 3 When...

Page 3: ... cut out of the PCB to reduce the current limit to 1 0 Amp Connectors TB1 16 5V 2 5A AC Transformer input connections TB2 13 8V DC Output alarm outputs and control input See page 4 for details TB3 12V 7AH Battery connection X3 Direct ribbon cable connection to certain Modules e g Mini Expander or 2 Door Access Module Type 2 or later Duplicates all connections on TB2 Part Number 605049 40cm or 6050...

Page 4: ...he Power Supply unit to run on the Battery if present If the Battery level drops below 11 volts LBATT will go into alarm A typical application could be Battery testing Using any Auxiliary output from a Concept module connect the output to PSDOWN as shown below When theAuxiliary is turned OFF the power supply is enabled When theAuxiliary is turned ON the power supply is operating from its battery o...

Reviews: