The third menu is the one defined as
EXTENDED 2
and to access the programmable functions follow the instructions given in
Tab. 4
:
EXTENDED
MENU 2
• Press the SELECT button and scroll the LED menu until you
reach the LEV LED;
• Press SET twice to access the EXTENDED menu 2.
The LED of the LEV function FLASHES with this frequency
LIVEL 2 - EXTENDED MENU 2
LED
FUNCTION
DESCRIPTION
LED ON
LED OFF
DEFAULT
L1
BRAKE
Enabling of the electronic brake
Enabled function
Disabled function
L2
STEP BY STEP 1
Step-By-Step logic
Open-Stop-Close-Stop (It DOESN'T close after the pause time in a
partial opening phase)
Disabled function
L3
ALWAYS CLOSE
Enables the sending of a CLOSE
command when the power is
turned on again
Enabled function
Disabled function
L4
FOLLOW ME
The motor automatically closes in
5 sec after passing through DS1
photocell
Enabled function
Disabled function
L5
PEDESTRIAN TIME
Storage of motor no.1 partial
stroke with slowdowns
Partial stroke of motor no.1 stored
10 sec., without slowdowns
L6
2°CH
MONOSTABLE /
BISTABLE/TIMED
MONO.
Setting the aux. relay of the
2°CH as Bistable / Monostable /
Temporised monostable
Bistable command
Monostable command (impulsive)
L7
REMOTELY
PROGRAMMING
Enable the remote control
memory function without acting
on the control unit
Enabled function
Disabled function
Table 4
The fourth and last menu is defined as
EXTENDED 3
and to access the programmable functions follow the instructions given in
Table 5
:
EXTENDED
MENU 3
• Press the SELECT button and scroll the LED menu until you
reach the LEV LED;
• Press SET 3 times to access the EXTENDED menu 3.
The LED of the LEV function FLASHES with this frequency:
LIVEL 3 - EXTENDED MENU 3
LED
FUNCTION
DESCRIPTION
LED ON
LED OFF
DEFAULT
L1
SOFT STOP
Setting of gradual slowdown at
the end of the movement
Enabled function
Disabled function
L2
SOFT START
Setting of gradual slowdown at
the beginning of the movement
Enabled function
Disabled function
L3
RELEASE STROKE
MAX FORCE/
RELEASE STROKE
Before opening, the closing thrust
is activated for the electric lock
release
Active function
Disabled function
L4
SLAM LOCK MAX
FORCE / SLAM
LOCK
Activation of the push in closing
for electric lock release
Active function
Disabled function
L5
ELS / CMD PED
Activation of the electric lock as
PPED input
Enabled function
Disabled function
L6
LAMP/INDICATOR
LIGHT/COURTESY
LIGHT/
Flashing light set as pilot light or
courtesy light
The courtesy light / warning light becomes an intermittent output, while
the lamp output becomes a courtesy light”
Flashing light
L7
PRELAMP / LAMP
IN PAUSE
Activation of the pre-flashing of
3 sec. before closing / Flashing
during the pause time
Active function: preflash in closing / Flash during pause
time
Disabled function
Table 5
Note:
The control unit allows to be programmed if all the safety devices (N.C. inputs on terminals) grant a contact closed.
Summary of Contents for QUAD 24V HP
Page 25: ...25 COMUNELLO Copyright 2021 All rights reserved NOTES...
Page 67: ...67 COMUNELLO Copyright 2021 All rights reserved NOTES...
Page 89: ...89 COMUNELLO Copyright 2021 All rights reserved NOTES...
Page 111: ...111 COMUNELLO Copyright 2021 All rights reserved NOTES...
Page 133: ...133 COMUNELLO Copyright 2021 All rights reserved NOTES...
Page 135: ...135 COMUNELLO Copyright 2021 All rights reserved 2 2 2 62 7 0 7 0 59 4 4 2 383 2 2...
Page 155: ...155 COMUNELLO Copyright 2021 All rights reserved NOTES...