5
COMUNELLO
®Copyright 2019 - All rights reserved
1 WARNINGS
The LD100 is a single channel inductive loop
detector. The use of microprocessor and surface
mount technology enables a large number of
functions to be incorporated into a small package.
The LD100 is compatible with most single channel
detectors on the market and is easy to set-up and
install.
Typical applications in the parking and access
control environments are safety loops, arming loops
and entry or exit loops.
2
PRODUCT DESCRIPTION AND
DESTINATION OF USE
Standard features of the detector are:
• Reset
Switch.
Pressing the reset switch enables the detector to be manually reset during
commissioning and testing. This results in the detector re-tuning the
sensing loop and becoming ready for vehicle detection.
• Switch selectable Sensitivity.
The detect sensitivity is the minimum change in inductance required to
produce a detect output. (%ΔL/L) Eight sensitivity settings are available on
the switches to allow flexibility in configuration.
1 High - 0.01% 5 - 0.2%
2 - 0.02% 6 - 0.5%
3 - 0.05% 7 - 1%
4 - 0.1% 8 Low - 2%
• Switch selectable Frequency.
The frequency of the loop is determined by the inductance of the loop and
the frequency switch setting. If the frequency switch is on, the frequency is
reduced. It may be necessary to change the frequency to prevent cross-
talk between adjacent loops.
• Sensitivity
Boost.
This feature sets the undetect level to maximum sensitivity and is used to
prevent loss of detection of high-bed vehicles.
• Filter
Option.
This option is used to provide a delay of 2 Seconds between detection of
the vehicle and switching of the output relay.
This delay is normally used to prevent false detection of small or fast
moving objects.
• Permanent Presence Option.
This feature ensures detection of the vehicle will be maintained when the
vehicle is parked over the loop for extended periods.
• Selectable Extend Time.
When switched on this feature extends the outputs for 2 Seconds.
• Pulse Relay Selection.
The Pulse relay may be configured to energise on detection of a vehicle or
when the vehicle leaves the loop.
• Selectable Pulse Time.
This feature sets the length of time that the pulse relay will be energised for.
1 Second or 0.2 Second.
• Power
Indicator.
This LED Indicator illuminates when power is present.
• Detect
Indicator.
This LED Indicator is illuminated when there is a vehicle over the loop
or the loop is faulty. This LED can also be used to determine the loop
frequency. On reset, count the number of times the LED flashes. Multiply
this number by 10KHz.For example: if the LED flashes 6 times, then the
loop frequency is between 60KHz and 70KHz.
• Loop Fault Indicator.
This LED Indicator is illuminated when the loop is either open circuit or
short circuit and is used to give a visual indication of a faulty loop.
3 TECHNICAL DATA
•
POWER
REQUIREMENT:
LD100 200 - 260VAC 50Hz 1.5VA
LD101 100 - 120VAC 60Hz 1.5VA
LD102 11 - 26VAC/DC 50/60Hz 95mA max.
•
PRESENCE/PULSE
RELAY :
0.5A/220VAC.
•
RESPONSE TIME:
Approximately 120ms after vehicle enters loop.
•
INDICATOR:
LED indicators show: Power ,Detect state and Loop
Fault.
•
DETECTOR TUNING
RANGE:
15 - 1500 uH.
•
PROTECTION:
Loop isolation transformer with lightning protection.
•
CONNECTOR:
11 Pin Connector on rear of unit.
•
DIMENSIONS:
80mm (height) X 40mm (width) X 79mm (Depth excl.
connector).
4 SWITCH SETTINGS
SWITCH SETTINGS
No.
FUNCTION
ON
OFF
10
7,8,9
7,8,9
7,8,9
7,8,9
7,8,9
7,8,9
7,8,9
7,8,9
6
5
4
3
2
1
EXTEND TIME
SENS 0.02%
SENS 0.01%
SENS 0.05%
SENS 0.1%
SENS 0.2%
SENS 0.5%
SENS 1%
SENS 2%
FREQUENCY
ASB
FILTER
PERM. PRESENCE
PULSE MODE
PULSE TIME
2SECS
-
S9
S8
S8/S9
S7
S7/S9
S7/S8
S7/S8/S9
LOW
ON
2SEC
ON
UNDET
1 SEC
OFF
S7/S8/S9
S7/S8
S7/S9
S7
S8/S9
S8
S9
-
HI
OFF
OFF
OFF
DET