Theory

 

of

 

operation

 

The

 

unit

 

has

 

two

 

external

 

antenna

 

ports

 

on

 

the

 

rear

 

of

 

the

 

unit.

  

One

 

is

 

for

 

the

 

transmitter

 

(TX

 

Ant)

 

and

 

the

 

other

 

is

 

for

 

the

 

receiver(RX

 

Ant).

  

These

 

ports

 

would

 

be

 

normally

 

attached

 

to

 

the

 

customer

 

supplied

 

duplexer.

   

 

WARNING:

 

WHEN

 

TESTING

 

THE

 

UNIT

 

BE

 

SURE

 

THE

 

DUPLEXER

 

IS

 

TUNED

 

PRIOR

 

TO

 

APPLYING

 

RF

 

POWER

 

FROM

 

THE

 

TRANSMITTER,

  

AS

 

RF

 

IN

 

EXCESS

 

OF

 

0

 

DBM

 

INTO

 

THE

 

RECEIVER

 

ANTENNA

 

PORT

 

WILL

 

CAUSE

 

DAMAGE

 

TO

 

THE

 

RECEIVER

 

FROM

 

END.

 

The

 

repeater

 

is

 

configured

 

with

 

one

 

RF

 

Power

 

amplifier

 

assembly

 

which

 

requires

 

approximately

 

100

 

mw

 

of

 

drive

 

from

 

the

 

module

 

marked

 

“Transmitter”

 

which

 

contains

 

the

 

control

 

logic

 

and

 

the

 

TX

RX

 

board.

  

The

 

100

 

mw

 

of

 

RF

 

is

 

then

 

routed

 

to

 

the

 

PA

 

Amplifier

 

assembly

 

and

 

amplifies

 

that

 

signal

 

to

 

45

110

 

watts,

 

which

 

is

 

then

 

routed

 

to

 

the

 

TX

 

Antenna

 

port.

 

The

 

repeater

 

is

 

configured

 

with

 

a

 

second

 

control

 

logic

 

and

 

TX

RX

 

board

 

in

 

which

 

the

 

receiver

 

only

 

is

 

used

 

for

 

full

 

duplex

 

operation.

  

The

 

receiver

 

front

 

end

 

has

 

the

 

addition

 

of

 

a

 

Front

 

end

 

protector

 

circuit

 

added

 

to

 

limit

 

the

 

RF

 

input.

  

The

 

receive

 

signal

 

enters

 

the

 

repeater

 

from

 

the

 

RX

 

antenna

 

port

 

(from

 

duplexer)

 

and

 

it

 

routed

 

to

 

the

 

module

 

marked

 

“Receiver”.

  

The

 

receive

 

signal

 

is

 

processed

 

and

 

the

 

recovered

 

receive

 

audio

 

is

 

then

 

routed

 

to

 

the

 

Rear

 

Panel

 

PCB

 

and

 

the

 

RM

1

 

Repeater

 

controller.

 

Stand

alone

 

Repeater

 

During

 

normal

 

operation

 

as

 

a

 

stand

alone

 

repeater,

 

the

 

unit

 

will

 

repeat

 

all

 

traffic

 

as

 

long

 

as

 

the

 

proper

 

RF

 

signal

 

with

 

the

 

necessary

 

CTCSS

 

or

 

DCS

 

code

 

is

 

present

 

and

 

the

 

“Radio

 

Aux

 

I/O”

 

jumper

 

plug

 

is

 

in

 

place.

 

DC

 

Power

 

The

 

Radio

 

requires

 

a

 

good

 

source

 

of

 

13.8

 

VDC

 

and

 

should

 

draw

 

less

 

than

 

20

 

amps

 

during

 

transmit.

 

 

 

 

 

 

Summary of Contents for LBR100C

Page 1: ...42327 Rio Nedo Suite A Temecula CA 92590 951 719 3266 www comtronixcommunications com USER MANUAL LBR100C LOW BAND BASE REPEATER STATION APRIL 2016 ...

Page 2: ...GAL OPERATION IS PUNISHABLE BY FINE OR IMPRISIONMENT OR BOTH REFER SERVICE TO QUALIFIED TECHNICIANS ONLY The antennas used for this transmitter must be fixed mounted on outdoor permanent structures and installed to provide a separation distance of at least 1 95 m from all persons and must not be co located or operating in conjunction with any other antenna or transmitter NOTE This instruction manu...

Page 3: ...ernemental Opération illégale est punissable d une amende ou IMPRISIONMENT OU LES DEUX CONSULTER LE SERVICE À DES TECHNICIENS QUALIFIÉS UNIQUEMENT Ne faites pas fonctionner votre émetteur récepteur lorsque quelqu un est à moins de 6 pieds de l antenne pour éviter la possibilité de fréquence radio brûlures ou blessures physiques connexes Remarque Ce manuel couvre uniquement les fonctions de base de...

Page 4: ...rge upper heatsink A microprocessor controlled interface module controls the channel selection LCD Display timers interfaces and signaling features All programming and alignment of the station is completed by the service shop technician There are no internal user adjustments in the station Specifications of LBR 100 VHF Low Band Continuous Duty Base Repeater Frequency Range 39 0 50 0 Mhz 160 channe...

Page 5: ...n routed to the PA Amplifier assembly and amplifies that signal to 45 110 watts which is then routed to the TX Antenna port The repeater is configured with a second control logic and TX RX board in which the receiver only is used for full duplex operation The receiver front end has the addition of a Front end protector circuit added to limit the RF input The receive signal enters the repeater from...

Page 6: ... CA 92590 951 719 3266 www comtronixcommunications com LBR 100 C QUICK SETUP 1 Unpack unit from carton and Locate the DC Power cord Hand Microphone for testing and 9 Pin Molex jumper plug FRONT VIEW OF REPEATER REAR VIEW OF REPEATER ...

Page 7: ...nterface Connector Functions Chart Pin Name I O Function Pin Name I O Function 1 RSI O RSSI OUTPUT 14 SB O SWITCHED 12VDC 5A 2 AI1 I AUX INPUT 1 15 RSV1 RESERVED 3 AI2 I AUX INPUT 2 16 RSV2 RESERVED 4 AI3 I AUX INPUT 3 17 AFO O LINE LEVEL RX AUDIO 5 AI4 I AUX INPUT 4 18 E GROUND 6 AI5 I AUX INPUT 5 EXT PTT 19 DEO O DETECTOR OUT 7 E GROUND 20 AO1 O AUX OUT 1 TOR 8 AO2 0 AUX OUT 2 COR 21 A03 O AUX O...

Page 8: ...ts to user supplied antennas or duplexer 6 Equipment is now ready to turn on Item Function 1 Power on off switch 2 Programmable Function Press on off Monitor 3 Programmable Function Press on then use CH SQL to adjust squelch level 4 Programmable Function Not assigned PF 3 5 Programmable Function Not assigned PF 4 6 Programmable Function Not assigned PF 5 7 Programmable Function Not assigned PF 6 8...

Page 9: ...the desired level does not effect repeater audio level 10 If local operation is used locate the microphone and plug into Microphone jack 9 11 If repeater operation is desired be sure that the 9 Pin Molex jumper plug in in place When the equipment is not working correctly contact your local service technician or you may contact the manufacturer directly COMTRONIX COMMUNICATIONS INC 42327 RIO NED SU...

Reviews: