Low Noise Amplifier Series
Revision 2
Redundancy
5–1
MN-LNAS
Chapter 5. REDUNDANCY
5.1
Typical System Noise Temperature
5.1.1
1:1 Redundant LNA System
T
system
= T
LNA
+ T
SWITCH
+ T
OPTION 3
+ T
OPTION 1
5.1.2
1:2 Redundant LNA System
RF Input 1:LNA online signal path
T
system
= T
LNA
+ T
SWITCH
+ T
OPTION 3
+ T
OPTION 1
RF Input 1:LNA 3 online signal path (LNA 1 Standby)
T
system
= T
LNA
+ 2*T
SWITCH
+ T
W2
+ T
OPTION 3
+ T
OPTION 1
RF Input 2:LNA 2 online signal path
T
system
= T
LNA
= T
W1
+T
SWITCH
+ T
OPTION 3
+ T
OPTION 1
RF Input 1:LNA 3 online signal path (LNA 2 Standby)
T
system
= T
LNA
+ 2*T
SWITCH
+ T
W1
+ T
W2
+ T
OPTION 3
+ T
OPTION 1
Table 5-1. Typical Noise Temperature in Kelvin at 23°C
Band (GHz)
3.62 to 4.205
3.4 to 4.2
10.7 to 12.75
Ka-Band
Item
WR229
WR229
WR75
WR42
TSWITCH
1.50
1.50
3.50
10.00
TW1
1.50
1.50
4.00
7.00
TW2
1.50
1.50
4.00
7.00
TOPTION1
0.50
0.50
2.00
10.00
TOPTION3
2.40
7.00
7.00
NA