OMMAND
/R
ESPONSE
P
AIRS
B.6.1 U
TILITY
C
OMMANDS
B.6.1.1 T
IME
Command
Details
Set Time:
<DEV/TIM
_
hh:mm:ss'cr'
hh = Hour*
Confirmation: >DEV/TIM
_
hh:mm:ss'cr''lf']
mm = Minutes ss = Seconds
Retrieve Time:
<DEV/TIM
_
'cr'
Confirmation: >DEV/TIM
_
hh:mm:ss'cr''lf']
* 24 hour military time is used.
B.6.1.2 D
ATE
Command
Details
Set Date:
<DEV/DAT_mm/dd/yy'cr'
mm = Month
Confirmation:
>DEV/DAT_mm/dd/yy'cr'lf']
dd = Day
yy = Year
Retrieve Date:
<DEV/DAT
_
'cr'
Confirmation: >DEV/DAT_mm/dd/yy'cr''lf']
B.6.1.3 P
HYSICAL
A
DDRESS
The default Physical Address from is 1.
Command
Details
Set Physical Address:
<DEV/SPA_xxx'cr'
xxx = 1 to 255
Confirmation: >DEV/SPA_xxx'cr''lf']
Retrieve Phys. Addr:
<DEV/SPA_'cr'
Confirmation: >DEV/SPA_xxx'cr''lf']
B.6.1.4 B
AUD
R
ATE
The default baud rate is 9600.
Command
Details
Set Baud Rate:
<DEV/SBR_xxxx'cr'
xxxx = 1200, 2400, 4800, 9600, 19K2, or 38K4
Confirmation: >DEV/SBR
_
xxxx'cr''lf']
Retrieve Baud Rate:
<DEV/SBR
_
xxxx'cr'
Confirmation: >DEV/SBR_xxxx'cr''lf']
Summary of Contents for DT-4572
Page 2: ......
Page 4: ......
Page 6: ......
Page 48: ...DT4572 X Band Down Converter Rev 0 System Operation MM DT4572 IOM 30 NOTES ...
Page 64: ...DT4572 X Band Down Converter Rev 0 Redundant System Operation MM DT4572 IOM 46 NOTES ...
Page 88: ...DT4572 X Band Down Converter Rev 0 Remote Control MM DT4572 IOM 70 NOTES ...
Page 98: ...DT4572 X Band Down Converter Rev 0 Maintenance and Troubleshooting MM DT4572 IOM 80 NOTES ...
Page 102: ...2114 West 7th Street Tempe Arizona 85281 USA 480 333 2200 Phone 480 333 2161 FAX ...