Display
(A) QAM Marker ID
• F1, F2, or F3. Must coincide with QM
setting in head-end. If --- displayed
device in M3 mode.
(B) Frequency
• Current frequency in use.
(C) Distance
• Adjusts measurement displayed to
compensate for distance to leak.
(D) Battery
• Current battery level
(E) Leakage/Noise
• “Leakage”=Valid leak being detected
• “Noise”=RF present and detected, but is
not a valid signal from QAM Marker (or
M3 if in M3 mode)
(F) Leak Level
• Current RF level being detected
• CLP indicates clipping
(G) Bar Graph
Keypad
Charge/Power
• Press to turn on/off
• LED orange during charging
• LED green when charging complete
• Red LED indicates charge Fault
Squelch (SQ)
• Minimum leakage level for warble output
• Press button to activate; cycle trigger switch to change
Distance (DIST)
• Compensate measurement to provide FCC mandated 10’ distance
• Press button to activate; cycle trigger to change
• LED On indicates good GPS fix
Scale
• Adjust bar graph/warble volume scaling
• Press button to activate; cycle trigger to change
• LED On indicates reduced gain (Device input overloaded)
BlueTooth (BT)
• Press once to store a single measurement to MPL.
• Hold for 1 second to start sending continuous real-time data
• LED On when connected to MPL
»
Slow flash indicates sending real-time data to MPL
»
Quick flash indicates send attempt but connection lost
Mode
• Press to cycle between QAM Marker and M3
• LED on indicates M3 Mode
Band
• Press to cycle between bands 1, 2 & 3
• Frequency indication changes with button press
• Hold for 1 second to enter All Band Monitor mode
»
Automatically returns to normal mode after 5 minutes
• LED On indicates All Band monitor mode
ComSonics, Inc. | 800.336.9681 | ComSonics.com
A B
C
D
E
F
G