background image

INSTALLATIONQUAD CONTROLLING 

Q4M/Q8M

 

MONITOR OUTPUTS 

Outputs QUAD and MAIN are individual video 
outputs  for  connecting  monitor  or  VCR.  For 
the  correct  function  of  the  connected  appa-
ratus the signal cables must have the imped-
ance load of 75

 

ALARM INPUTS 

One  alarm  input  is  suitable  for  one  video  in-
put.  Alarm  loops  are  connected  between 
alarm input  and common conductor  - ground 
(GND). 
 

ALARM OUTPUT 

Quad  has  its  own  potentialless  alarm  output 
made  of  the  normally  open  contacts  of  the 
relay.  
 

ALARM CONNECTOR 

Alarm connector is used for connecting alarm 
inputs  and  outputs.  The  connection  of  25 
outlet  connector  CANNON  is  illustrated  on 
the pictures 5 and 6 (page 4). 
 

POWER SUPPLY INPUT 

Quads  Q4M  (Q8M)  are  supplied  from  a  uni-
flow  supply  of  12  V.    Energy  input  is  4  W 
maximum.  For  connecting  supply  voltage  is 
used  a  concentric  connector  5,5  x  2,1  mm. 
The positive supply pole is on the inside con-
tact  of  the  concentric  connector,  the  con-
nector jacket is the negative pole. 
 

BASIC MODE 

After  turning  on,  the  quad  cyclically  switches 
among  active  cameras  according  to  the  se-
quence,  which  has  been  set  up.  The  auto-
matic switching is signaled by the SEQ light-
emitting  diode  (LED),  the  camera  displayed 
on  the  main  video  output  (MAIN)  is  signaled 
by  the  diode  of  the  buttons  1 

– 4  or  QUAD 

(1 

– 8, QUAD1 AND QUAD2 for Q8M). 

 

MANUAL SWITCHING 

Press  the  corresponding  button  to  display 
cameras  1 

–  8  or  quad  screens  QUAD, 

QUAD1 and QUAD2. 
  

AUTOMATIC SWITCHING 

The  automatic  switching  starts  by  pressing 
the button SEQ. 
If the quad does not start to switch automati-
cally, check the camera settings in the menu 
SEQUENCE and TIME (page 6). 

 
CAMERA FREEZE IN QUAD SCREEN 

Be sure, there is a quad picture displayed on 
the output MAIN.  
Press and keep the button 1 

– 8, the camera 

screen  will  stop  (freeze)  or  run-up  if  it  was 
stopped.  When  the  picture  is  frozen,  the 
camera LED is shining together with the quad 
picture LED QUAD, QUAD1 and QUAD2.  
If  the  LED  above  the  buttons  1 

– 4  (1 - 8  by 

Q8M)  is  shining,  the  video  signal  of  corre-
sponding cameras is missing. 

 

Summary of Contents for Q4M

Page 1: ...BLACK AND WHITE QUAD Q4M Q8M Installation and user manual...

Page 2: ...ot use the unit near water for example near a bath tub or in any area showing evidences of humidity POWER SUPPLY This equipment can be fed only by the type of supply quoted by a production code on the...

Page 3: ...e main output MAIN It is possible to set up cameras which are at the right time available for automatic switching This makes possible to disconnect temporarily uninteresting or disconnected cameras An...

Page 4: ...4 QUAD2 Press the button QUAD2 to display the quad screen containing cameras 5 8 only for quads Q8M 5 MENU Press the button MENU to display the control menu on the screen Pict 3 Back panel Q4M IN 1 QU...

Page 5: ...9 Reserve 20 Common conductor ground GND 21 Reserve 22 Reserve 23 Reserve 24 Reserve 25 Common conductor ground GND Pict 6 Alarm connector CANNON 25 for Q8M 13 12 11 10 9 8 7 6 5 4 3 14 15 16 17 18 19...

Page 6: ...concentric connector the con nector jacket is the negative pole BASIC MODE After turning on the quad cyclically switches among active cameras according to the se quence which has been set up The auto...

Page 7: ...notice INCORRECT SEQUENCE will appear In that case is necessary to set up cameras in the SEQUENCE menu properly TIME SWITCHING PERIOD By using the buttons 1 and 3 1 and 5 by Q8M is possible to prolong...

Page 8: ...he interlace correction Off interlace correction of the life screen can cause a gliding effect which is evoked by projection of different half fields of the same camera If you choose the item INT ON a...

Page 9: ......

Page 10: ...s appear over the individual screen quadrants Strong interference from power distribution has debased the cam era signal Check the camera connection Check the camera and monitor ground conductor Autom...

Page 11: ...INPUTS Number 4 8 by Q8M Loop connection input ground GND Activity normally open Maximum alarm loop impedance 1 k Connector CANNON 25 pin socket ALARM OUTPUT Output 2 low voltage relay contacts Maxim...

Page 12: ...2000 COMPUTRONIC Printed in the Czech Republic Producer reserves the right to alternation without prior notice...

Reviews: