24
Go to the thermostat calibration
settings using and buttons.
3 sec.
Hold
button for 3 seconds to
enter the menu.
5.4 Heat/cool mode change
Confirm by
button.
1
2
3
The heating / cooling mode for the thermostat can be changed manually.
Page 1: ...VS30W VS30B THERMOSTAT FULL USER MANUAL ...
Page 2: ......
Page 3: ... source control 14 III B work with RM 16A relay module connection to a solid fuel boiler controller 14 III C work with RM 16A relay module connecting an electrical device with a higher power 15 3 Before you start first power up 16 3 1 LCD icon description 16 3 2 Button description 16 3 3 First power up sequence 17 4 Work modes 18 5 User settings basic settings 19 5 1 Schedule mode programming sche...
Page 4: ...ations in accordance with standards and regulations in force in the given country and in the EU Never try to connect the device other than as described in the manual Before assembly repair or maintenance as well as during any connection works it is absolutely necessary disconnect the mains supply and make sure that the terminals and electric wires are not live The device may not be exposed to extr...
Page 5: ...should reach while it is on It will allow you to select different temperatures in your home at different times of the day and days of the week to meet your particular needs Turning a programmable room thermostat to a higher setting will not make the room heat up any faster How quickly the room heats up depends on the design of the heating system for example the size of boiler Neither does the sett...
Page 6: ...urces Thermostat can t be exposed to sunlight or any extreme conditions like for example draft Because of fire and explosion risk there is not allowed to use thermostat in atmosphere of explosive gases and flammable liquids eg coal dust In case if any of listed dangers occur you have to use additional protection measures anti dust and explosive gases tight cover or prevent their formation Furtherm...
Page 7: ...e NSB VS30 VS30 L N power supply 230V NSB Night temperature reduction 230V output SL 230V AC output signal S1 S2 additional temperature sensor eg FS300 2 3 Connection description NSB input in SLAVE thermostat NSB output Legend Thermal actuator Temperature sensor Symbols explanation T ...
Page 8: ...t works as a MASTER group controller it means it takes control of SLAVE thermostats e g VS35W MASTER thermostat controls SLAVE thermostat only when SLAVE thermostat is in AUTO mode Comfort SUN and economy MOON setpoint temperatures are set individually on each thermostat but switching between those temperature is based on time schedule taken from VS30W VS30B thermostat which works like a group con...
Page 9: ...Zones 3 4 N N N N N N L max 6 per zone max 6 per zone max 6 per zone VS30W VS30B VS35W VS35B VS35W VS35B L N power supply 230V NSB Night temperature reduction 230V output in MASTER thermostat 230V input in SLAVE thermostat SL 230V AC actuator control signal fuse Legend Symbols explanation Thermal actuator Pump Boiler Boiler connection Boiler s contacts for ON OFF thermostat according to the boiler...
Page 10: ...re THB23030 T30NC230 Power Supply 230V AC Actuators wires 2 x 0 75mm2 Pump control wires 2 x 1mm2 Boiler control wires 2 x 1mm2 KL06 PL07 PL06 PUMP optional BOILER 4 wires x 0 75 mm2 4 wires x 0 75 mm2 SLAVE MASTER VS30W VS30B VS35W VS35B VS35W VS35B ...
Page 11: ...er L N L N T30NC max 6 na strefę RT10 RT20 Np Np L N 1 6 Strefy PL06 L N L N T30NC max 6 na strefę RT520 COM NO lub NC NO PODŁĄCZENIE KOTŁA L AC 230V L N N 1 6 Strefy KL06 M Power L N L N T30NC max 6 na strefę RT10 RT20 Np Np L N 1 6 Strefy PL06 L N L N T30NC max 6 na strefę RT520 COM NO lub NC NO L N MAX 5 2 A AC 230V lub 24V L AC 230V L N N 1 6 Strefy KL06 M Power L N L N T30NC max 6 na strefę R...
Page 12: ...hermostat no effect on other thermostats likeVS35W VS35B schedules can be set individually on eachVS30W VS30B thermostats if system is equipped with more than oneVS30W VS30B thermostat PLEASE NOTE The same operating rules apply to wiring center KL06 THB23030 PUMP optional T30NC230 BOILER 3 wires x 0 75 mm2 3 wires x 0 75 mm2 Power Supply 230V AC Actuators wires 2 x 0 75mm2 Pump control wires 2 x 1...
Page 13: ...1 8 Zones 3 4 N N N N N N L max 6 per zone max 6 per zone max 6 per zone VS30W VS30B VS30W VS30B VS30W VS30B L N power supply 230V NSB Night temperature reduction 230V output SL 230V AC actuator control signal fuse not used in 3 wire installation Legend Symbols explanation Thermal actuator Pump Boiler Boiler connection Boiler s contacts for ON OFF thermostat according to the boiler s instructions ...
Page 14: ...O COM COM NC SL N L L N 1 8 Strefy KL08NSB Power L N L N SL Connection of a 230V AC voltage thermostat to a boiler or other device with an ON OFF contact VS30W VS30B BOILER CONNECTION input PLEASE NOTE Activate the thermostat in the solid fuel boiler controller RM 16A L AC 230V N L AC 230V N NO NO COM COM wejście NC SL L N SL N L PODŁĄCZENIE KOTŁA VS30 Np VS30 Np 091FL Np Podłączenie regulatora na...
Page 15: ... 1 8 Strefy KL08NSB Power L N L N SL MA 16 5 input VS30W VS30B III C work with RM 16A relay module connecting an electrical device with a higher power than the thermostat relay allows PLEASE NOTE The maximum current consumption of an electrical device should not exceed 16A L N power supply 230V SL 230V AC control signal NO COM NC voltage free output fuse Legend Symbols explanation Pump Valve actua...
Page 16: ...19 Cooling 20 Heating PLEASE NOTE The LCD screen can be activated by using any button OR 1 Increase or decrease setpoint temperature 2 Increase or decrease Day Clock Timer Party and Holiday 3 Select installer parameter value 1 Mode selection 2 Moving between parameters 1 OK key Short press to confirm selection 2 Long press to save and exit 3 When Main Screen long press to enter the user settings H...
Page 17: ...tons Confirm by button After all the main screen will be displayed Set time format or buttons Confirm by button Set time hours and minutes using or buttons Confirm by button then thermostat will display the software version To power on the thermostat you have to connect it to the 230V power supply then 2 1 4 5 6 3 7 8 ...
Page 18: ...d temperature in heating mode or the lowest if thermostat works in the cooling system Acting alone works as a manual mode Temperature range from 5 C to 35 C Standardtemperaturemode pre definedsetpointtemperature Usuallysetduringthedaywhenwearearoundthehouse Actingaloneworks as a manual mode Economic temperature mode pre defined setpoint temperature Usually set at night or when we are out of the ho...
Page 19: ...re are 4 possible schedule variants Use and buttons to select schedule variant and confirm by button Separate schedule for WORKING DAYS Separate schedule for WEEKENDS One schedule for WHOLEWEEK Seven separate schedules for SINGLE DAYS 1 2 3 Enter into the schedule settings Hold button for 3 seconds to enter the menu 3 sec ...
Page 20: ...m is skipped There are 6 programs time periods in the schedule Hold button for 3 seconds to save and exit schedule editing To run the schedule activate thermostat s automatic mode use and buttons to move the frame to the A icon Schedule programming example for theWORKING DAYS variant 10 4 5 6 8 9 7 Use and buttons to choose comfort or economic setpoint temperature Schedule editing will jump to the...
Page 21: ... 4 5 6 2 days Saturday to Sunday Program Program Time Heat set point Cool set point 1 7 00 2 23 00 3 4 5 6 Program Profile 3 5 days Monday to Friday Program Program Time Heat set point Cool set point 1 5 00 2 8 00 3 14 00 4 22 00 5 6 2 days Saturday to Sunday Program Program Time Heat set point Cool set point 1 7 30 2 22 30 3 4 5 6 Program Profile 4 5 days Monday to Friday Program Program Time Hea...
Page 22: ...m by button Set minutes using and buttons Confirm by button Set day using and buttons Confirm by button 3 DATE settings will automatically appear after clock setup Hold button for 3 seconds to enter the menu Go to the time and date settings using button Choose time and date settings option by button First select time format 12 24h using and buttons Confirm by button 7 8 9 4 5 6 2 3 3 ...
Page 23: ...0 C in 0 5 C steps To calibrate thermostat s temperature sensor please follow steps below 1 4 7 6 Set temperature calibration value using and buttons To increase decrease value use and buttons Go to the thermostat calibration settings using and buttons 5 2 3 8 Hold button for 3 seconds to enter the menu Confirm by button Confirm by button Thermostat will go back to the main screen after saving the...
Page 24: ...ermostat calibration settings using and buttons 3 sec Hold button for 3 seconds to enter the menu 5 4 Heat cool mode change Confirm by button 1 2 3 3 The heating cooling mode for the thermostat can be changed manually ...
Page 25: ... temperature control 0 0 PWM Pulse width modulation algorithm ensures reduction of overdrive states and economic operation of the system It is an advanced algorithm designed to precisely maintain room temperature 1 SPAN 0 5 C 1 F 2 SPAN 1 C 1 5 F d02 Offset temperature 3 0 C to 3 0 C Offset room temperature measuring is a function which allows user to recalibrate internal thermostat s temperature ...
Page 26: ...ireless from 13 to 13 hours It gives you the possibility to fit the thermostat time zone to yours every 1 hour step 0 d11 Daylight SavingTime DST 0 Off 1 1 On d12 Heating temperature limit 5 C 35 C The maximum heating temperature that can be set by the user 35 C d13 Cooling temperature limit 5 C 40 C The minimum cooling temperature that can be set by the user 5 C d14 Maximum floor temperature this...
Page 27: ...few moments to finish factory reset procedure thermostat will display the software version after all screen with time and date selection will appear Use or buttons to choose code 47 Press button to confirm Select del and confirm choice by pressing button 3 5 sec 5 sec 5 sec Hold buttons for 5 seconds to enter the installer mode ...
Page 28: ...Tuse solvents polishes detergentsorabrasivecleaners asthesecandamagethethermostat Therearenouserserviceablepartswithintheunit anyservicing or repairs could only be carried out by Salus Controls or their appointed agents 9 Cleaning and Maintenance 8 Error codes 10 Technical Informations 86 mm 42 mm 86 mm 86 mm Error code Description Err02 The maximum minimum floor temperature has been exceeded Err0...
Page 29: ...willbefreefromanydefectinmaterialsorworkmanship andshallperforminaccordancewithitsspecification foraperiodoffiveyearsfromthedateofinstallation SALUSControlssoleliabilityforbreachofthiswarrantywillbe atitsoption torepairorreplacethe defective product ...
Page 30: ...ROLS Sp z o o Sp k Rolna 4 43 262 Kobielice Poland www salus controls com SALUS Controls is a member of the Computime Group Maintaining a policy of continuous product development SALUS Controls plc reserve the right to change specification design and materials of products listed in this brochure without prior notice Ver 2 Issued 01 IX 2020 Soft version 1 2 ...