12
II - 3 wire installation with KL08NSB wiring centre
3 wire installation with KL08NSB wiring center. Description of the operation rules:
- VS30W/VS30B thermostat’s functionality is limited because of 3 wire installation. NSB function is disabled and VS30W/VS30B thermostat doesn’t work
as a MASTER thermostat - no effect on other thermostats like VS35W/VS35B.
- schedules can be set individually on each VS30W/VS30B thermostats if system is equipped with more than one VS30W/VS30B thermostat.
PLEASE NOTE!
The same operating rules apply to wiring center KL06.
THB23030
PUMP (optional)
T30NC230
BOILER
3 wires x 0.75 mm2
3 wir
es x
0.75
mm2
Power Supply
230V AC
Actuators wires
2 x 0.75 mm2
Pump control wires
2 x 1 mm2
Boiler control wires
2 x 1 mm2
KL08NSB
KL04NSB (optional)
VS30W/VS30B
VS30W/VS30B VS30W/VS30B