background image

- 9 -

5.3 Activating/deactivating of the delay functions

To activate/deactivate the Turn on and off delay functions, press and hold the 

Z1 and Z2 buttons on the zone controller for 5 seconds until the blue LED 

flashes at one second intervals. You can activate/deactivate the functions by 

pressing the buttons Z1 and Z2. The LED Z1 shows the Turn on delay status, 

while the LED Z2 shows the Turn off delay status. The function is activated 

when the corresponding red LED is lit.
To save the settings and return to the default state wait 10 seconds. When the 

blue LED stops flashing the zone controller resumes the normal operation.

The delay functions can be reset to the factory defaults (deactivated state) by 

pressing the “

RESET

” button!

6. USING THE ZONE CONTROLLER

After installing the device, putting it into operation and turning it on with its switch 

(position 

ON

), it is ready for operation, which is indicated by the illuminated 

state of the red LED with sign “

POWER

” and the blue LED with sign “

A/M

” on 

the front panel. Then, following the heating command of any of the thermostats, 

the zone valves/pumps associated with the thermostat open/start and the boiler 

also starts, also taking the Turn on delay function into account (see Section 

5

). 

By pressing the “

A

/

M

” (

AUTO

/

MANUAL

) button (the factory default 

AUTO

 sta-

tus is indicated by the illumination of the blue LED next to the “

A

/

M

” button) it 

is possible to detach the thermostats and manually adjust the heating zones 

for each thermostat to start. This may be necessary temporarily if, for exam-

ple, one of the thermostats has failed or the battery in one of the thermostats 

has run down. After pressing the “

A

/

M

” button, the heating of each zone can 

be started manually by pressing the button indicating the zone number. The 

operation of the zones activated by manual control is also indicated by the 

red LED of the zones, but in manual control the blue LED indicating the “

A

/

M

” 

status is not illuminated. (In case of manual control, the heating of the zones 

operates without temperature control.) From manual control, you can return 

to the thermostat-controlled factory default operation (

AUTO

) by pressing the 

A

/

M

” button again.

Warning! The manufacturer does not assume responsibility for any direct 

or indirect damages and loss of income occurring while the appliance is 

being used.

Summary of Contents for Q4Z

Page 1: ...Operating Instructions zone controller for controlling 1 to 4 heating zones COMPUTHERM Q4Z...

Page 2: ......

Page 3: ...h other or in case of need all zones can operate at the same time To control more than 4 zones at a time we recommend using 2 or more COMPUTHERM Q4Z zone controllers 1 zone controller needed per 4 zon...

Page 4: ...connection points T1 T2 T3 T4 one for a room thermostat and one for a zone valve pump Z1 Z2 Z3 Z4 The thermostat of the 1st zone T1 controls the zone valve pump of the 1st zone Z1 the thermostat of t...

Page 5: ...reover the four heating zones also have a joint connection point for a zone valve pump Z1 4 If any of the four thermostats T1 T2 T3 and or T4 switches on then beside the 230 V AC voltage appearing at...

Page 6: ...aratus to be connected to it is connected to the 230 V mains voltage Modifying the device can cause electric shock or product failure Attention We recommend that you design the heating system you want...

Page 7: ...ats connection points for power supply fix phase working when the power switch is turned on fuse 15 A connection points controlling the boiler connection points of the heating zones In case of using e...

Page 8: ...lashes with 3 second intervals the LED stops flashing and indicates the current operating mode Automatic Manual Then the working mode can be changed by pressing the A M button again After 10 seconds t...

Page 9: ...of the thermostats the zone valves pumps associated with the thermostat open start and the boiler also starts also taking the Turn on delay function into account see Section 5 By pressing the A M AUTO...

Page 10: ...tchable voltage of the relay that controls the boiler 230 V AC 50 Hz Switchable current of the relay that controls the boiler 8 A 2 A inductive load Duration of activable Turn on delay function 4 minu...

Page 11: ......

Page 12: ...ves EMC 2014 30 EU LVD 2014 35 EU and RoHS 2011 65 EU Copyright 2020 Quantrax Ltd All rights reserved Manufacturer QUANTRAX Ltd H 6726 Szeged F lem le u 34 Hungary Telefon 36 62 424 133 Fax 36 62 424...

Reviews: