Airtop2 owner’s manual
I
3
M – Integrated Interactive Information Monitor
The Integrated Interactive Information Monitor (I3M) is a display and navigation keypad on the front panel which provides real-
time system information such as power consumption, temperature and frequency.
I
3
M requires a firmware (pre-installed) and Windows or Linux software running on Airtop2 for full functionality.
To install I
3
M please visit:
http://fit-pc.com/wiki/index.php/Airtop2_Software#I3M
BIOS
For BIOS documentation see
http://fit-pc.com/wiki/index.php/Airtop2_Software
Entering BIOS Setup Utility
Turn off Airtop2.
Turn on while holding down the DEL key.
Troubleshooting
Airtop2 does not boot
Power problem
Check that the LED on the PSU is lit green. If not, check that it is connected to a functional AC outlet.
Check that the power button on the front panel is lit. If not, check that the DC plug is inserted correctly into the jack at the rear
panel of Airtop2. You may try to plug it at the backup DC jack.
RAM problem
The most common reason is RAM that is not installed or incompatible.
Airtop2 supports DDR4 DIMM.
Note that registered (buffered) DIMM is not supported.
Note that only Xeon supports ECC (Core supports non-ECC only. It will still function with ECC memory).
By default Airtop2 ships with the FM-AT2 FACE Module that has 4 LEDs marked B, R, H, D
Turn on Airtop2 and observe the R LED. Normally it would turn amber for a short period (during RAM detection) and upon
successful detection it will turn green.
If it turns green then RAM is fine.
If it does not turn green, disconnect power and open the clamshell door. Check that RAM is compatible and installed correctly.
If you have multiple DIMM modules you may leave only one and change its slot.
Try powering up again until RAM is detected properly.
Storage or missing operating system
Ensure a storage device is installed and detected in BIOS settings.
Check boot order in BIOS settings.
Ensure that an operating system is installed on the selected storage device.
I
3
M does not show temperatures and other data
This information is obtained from a service running in the operating system.
Please Install. Consult:
http://fit-pc.com/wiki/index.php/Airtop2_Software#I3M
Technical support
For any issue please email
or call +972-4-8290134