Installation:
1) Determine the type of cables to be used, the camera locations and the monitor
locations.
2) For the cameras you will need either a length of RG-59U or Cat-5 or 3 to run from each
camera to the ARS.
3) Using the appropriate connector, connect the video in from each camera to the unit.
Do
not connect anything to the opposite type connector.
Example: If you use the Cat-5
input, leave the BNC connector open, do not try to use it as a loop-thru.
4) From each monitor run one RG-59U and a 1 pair 20 ga or larger pair wire for the
remote button which is connected as shown below. If more than one button and monitor is
required for each output, simply parallel the buttons and DA the video to the monitors. We
do not recommend loop thru video.
Button
Fig. 2
Video Input Connectors
Fig. 3
Remote Inputs