Compressed Air Advisors HEF 005 Maintenance And Operating Manual Download Page 6

MAINTENANCE AND OPERATING MANUAL

INSTALLATION

HEF 005÷240

4

ENGLISH

EN

The data in this manual are not binding and may be changed by the manufacturer without notice. 

Reproduction of this manual is strictly prohibited.

INSTALLATION

ATTENTION

Operations to be performed by qualified personnel. Never operate with plants under pressure. The user is
responsible to ensure that the filter will never be operated with pressure exceeding the nominal values. Eventual
over-pressure could be dangerous both for the operator and the equipment.

1 . 1

M o d e l s   H E F   0 0 5   -   0 7 0

The filter assembly and installation procedures are as follows:

• If provided, install the clogging indicator or the Differential Pressure Gauge (optional) into the 

filter head.

• Connect the filter head to the compressed air piping and check that the airflow respects the 

direction of the arrow positioned on the filter head cap.

• Clean accurately the extremities of the piping and the filter head, after the installation, to remove 

any shaving, slaver or scrap from tooling.

• Lubricate the O-ring and the sealing surfaces of the filter head and cartridge, use multipurpose 

grease (SILICON FREE).

• Fit the filter cartridge on the filter head simply by pressing, tightness is ensured by one o-ring.
• Fit the filter bowl and tight it accurately.
• Remove from the bottom of the filter body the plastic plug (which does not withstand pressure) 

inserted in the connection for the condensate discharge.

• If foreseen, install a condensate discharger (not supplied with the filter).

If not foreseen, close the condensate discharge connection with a 1/2" metal plug with appropriate 
threading type.

• The filters must always be installed in a vertical position with sufficient space around and below 

them (see minimum distance D in the technical data table) so as to be able to disassemble the bowl 
and the cartridge as shown .

• Stick the adhesive label showing the month and year for the next filtering element change (max. 

one year) on the filter bowl.

• Pressurize the plant like shown at paragraph "Starting up" and check for air leakage.

1 . 2

M o d e l s   H E F   0 9 4   -   2 4 0

The filter assembly  and installation procedures are as follows:

• If provided, install the clogging indicator or the Differential Pressure Gauge (optional) into the 

filter head.

• Connect the filter head to the compressed air piping and check that the airflow respects the 

direction of the arrow positioned on the filter head cap.

• Clean accurately the extremities of the piping and the filter head, after the installation, to remove 

any shaving, slaver or scrap from tooling.

• Lubricate the O-ring and the sealing surfaces of the filter head and cartridge. Use multi-purpose 

grease (SILICON FREE).

• Fit the filter cartridge on the filter head centering the filter bottom hole with the screwed rod . Tight 

the hexago- nal nut fixing the element.

• Fit the filter bowl and tight it accurately.
• Remove from the bottom of the filter body the plastic plug (which does not withstand pressure) 

inserted in the connection for the condensate discharge.

• If foreseen, install a condensate discharger (not supplied with the filter).

If not foreseen, close the condensate discharge connection with a 1/2" metal plug with appropriate 
threading type.

• The filters must always be installed in a vertical position with sufficient space around and below 

them (see minimum distance C in the technical data table) so as to be able to disassemble the bowl 
and the cartridge as shown.

• Stick the adhesive label showing the month and year for the next filtering element change (max. 

one year) on the filter bowl.

• Pressurize the plant like shown at paragraph "Starting up" and check for air leakage.

Summary of Contents for HEF 005

Page 1: ...COMPRESSED AIR FILTER MAINTENANCE AND OPERATING MANUAL HEF 005 240 38178800738 Original instructions...

Page 2: ......

Page 3: ...without notice Reproduction of this manual is strictly prohibited INDEX INDEX 1 INTRODUCTION 2 SAFETY 2 INTENDED USE 2 FILTRATION GRADES AND APPLICATIONS 3 INSTALLATION 4 1 1 Models HEF 005 070 4 1 2...

Page 4: ...FETY ATTENTION Absolutely avoid to place the filter in zones influenced by warm air flows or near flammable materials Avoid vibrations during filter operation they could cause damages Do not use the f...

Page 5: ...n to 0 1 micron liquid and oil included Maximum contents of residual oil 0 1 mg m3 Normally used as a prefilter at the entrance of the dryer with frigorific cycle to prevent deterioration of pipes in...

Page 6: ...nd and below them see minimum distance D in the technical data table so as to be able to disassemble the bowl and the cartridge as shown Stick the adhesive label showing the month and year for the nex...

Page 7: ...ine from the filter slowly open the on off valve V2 up line from the filter and let the air flow from the manual or automatic drain valve for a few minutes close the drain valve and open the on off va...

Page 8: ...kwise In this case automatic operation is overridden until the closed position is restored For the installation insert the automatic condensate discharger SCF into the casing and screw it onto the con...

Page 9: ...without notice Reproduction of this manual is strictly prohibited On Request 1 Condensate separator 2 Wall mounting kit 3 Serie connection kit 4 Differential pressure gauge 2 3 2 4 5 1 3 Vaselline To...

Page 10: ...ies from case to case It is recommended that the cartridge is replaced at least once a year but depending on the application this can be required every 6 months 1 Remove the bowl 2 HEF 094 240 Remove...

Page 11: ...1 HEF 175 21 2 1680 935 163 43 770 14 0 6 9 HEF 200 3 2160 795 240 59 630 20 0 12 9 HEF 240 3 2760 1000 240 59 780 24 40 14 0 Flow rate condition FAD 20 C 1 bar A operating pressure 7 barg air operati...

Page 12: ...nufacturer without notice Reproduction of this manual is strictly prohibited CORRECTION FACTORS Operating pressure bar 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Operating pressure psi 29 44 58 72 87 100 11...

Reviews: