MAINTENANCE AND OPERATING MANUAL
INSTALLATION
HEF 005÷240
4
ENGLISH
EN
The data in this manual are not binding and may be changed by the manufacturer without notice.
Reproduction of this manual is strictly prohibited.
INSTALLATION
ATTENTION
Operations to be performed by qualified personnel. Never operate with plants under pressure. The user is
responsible to ensure that the filter will never be operated with pressure exceeding the nominal values. Eventual
over-pressure could be dangerous both for the operator and the equipment.
1 . 1
M o d e l s H E F 0 0 5 - 0 7 0
The filter assembly and installation procedures are as follows:
• If provided, install the clogging indicator or the Differential Pressure Gauge (optional) into the
filter head.
• Connect the filter head to the compressed air piping and check that the airflow respects the
direction of the arrow positioned on the filter head cap.
• Clean accurately the extremities of the piping and the filter head, after the installation, to remove
any shaving, slaver or scrap from tooling.
• Lubricate the O-ring and the sealing surfaces of the filter head and cartridge, use multipurpose
grease (SILICON FREE).
• Fit the filter cartridge on the filter head simply by pressing, tightness is ensured by one o-ring.
• Fit the filter bowl and tight it accurately.
• Remove from the bottom of the filter body the plastic plug (which does not withstand pressure)
inserted in the connection for the condensate discharge.
• If foreseen, install a condensate discharger (not supplied with the filter).
If not foreseen, close the condensate discharge connection with a 1/2" metal plug with appropriate
threading type.
• The filters must always be installed in a vertical position with sufficient space around and below
them (see minimum distance D in the technical data table) so as to be able to disassemble the bowl
and the cartridge as shown .
• Stick the adhesive label showing the month and year for the next filtering element change (max.
one year) on the filter bowl.
• Pressurize the plant like shown at paragraph "Starting up" and check for air leakage.
1 . 2
M o d e l s H E F 0 9 4 - 2 4 0
The filter assembly and installation procedures are as follows:
• If provided, install the clogging indicator or the Differential Pressure Gauge (optional) into the
filter head.
• Connect the filter head to the compressed air piping and check that the airflow respects the
direction of the arrow positioned on the filter head cap.
• Clean accurately the extremities of the piping and the filter head, after the installation, to remove
any shaving, slaver or scrap from tooling.
• Lubricate the O-ring and the sealing surfaces of the filter head and cartridge. Use multi-purpose
grease (SILICON FREE).
• Fit the filter cartridge on the filter head centering the filter bottom hole with the screwed rod . Tight
the hexago- nal nut fixing the element.
• Fit the filter bowl and tight it accurately.
• Remove from the bottom of the filter body the plastic plug (which does not withstand pressure)
inserted in the connection for the condensate discharge.
• If foreseen, install a condensate discharger (not supplied with the filter).
If not foreseen, close the condensate discharge connection with a 1/2" metal plug with appropriate
threading type.
• The filters must always be installed in a vertical position with sufficient space around and below
them (see minimum distance C in the technical data table) so as to be able to disassemble the bowl
and the cartridge as shown.
• Stick the adhesive label showing the month and year for the next filtering element change (max.
one year) on the filter bowl.
• Pressurize the plant like shown at paragraph "Starting up" and check for air leakage.