Compressed Air Advisors HEF 005 Maintenance And Operating Manual Download Page 5

MAINTENANCE AND OPERATING MANUAL

FILTRATION GRADES AND APPLICATIONS

HEF 005÷240

3

ENGLISH

EN

The data in this manual are not binding and may be changed by the manufacturer without notice. 

Reproduction of this manual is strictly prohibited.

FILTRATION GRADES AND APPLICATIONS

The filters of this serie are used for filtering small solid particles and removing water and oil condensate from 
compressed air and gases.

Filter grade

Characteristics

Installation  

Application example

Serie "P"

Yellow

Filter capable to separate 
emulsion and particles 
down to 3 micron.

Ideal as a protection filter of the 
downstream line, in case of 
compressed aire with a high oil, 
condensate and/or dusts 
contamination: as a prefilter for 
line filters with a superior filtering 
degree, vacuum pumps, pneumatic 
pumps for inflation, etc.

Serie "M"

Green

Filter capable to separate 
particles down to 0,1 
micron, liquid and oil 
included. Maximum 
contents of residual oil 
0,1 mg/m

3

.

Normally used as a prefilter at the 
entrance of the dryer with 
frigorific cycle, to prevent 
deterioration of pipes in a plant of 
compressed air, superficial 
treatments, drain of vacuum 
pumps, compressed air motors, 
post filter for adsorption dryers, 
etc.

Serie "S"

Red

Oil removing filter 
capable to separate 
residual oil and extremely 
small particles down to 
0,01 mg/m

3

. Maximum 

contents of residual oil 
0,01 mg/m

3

. It produces  

air technical free from oil.

Normally used as a prefilter at the 
entrance of the dryer by absorption 
and active carbon filters; post 
filter at the delivery of the 
frigorific cycle dryers. Also ideal 
for the protection of the control 
systems, pneumatic transport, 
varnishing systems, etc.

Serie "A"

Silver

Activated carbon filter for 
the elimination of oil 
vapours and odour. It 
lowers the maximum 
contents of residual oil to 
0,005 mg/m

3

.

Used in the pharmaceutical 
industry, dental applications, 
photograph labs, packaging and 
galvanic treatments, etc.

   P

P

   M

    M

M

   S

    S

S

   A

Summary of Contents for HEF 005

Page 1: ...COMPRESSED AIR FILTER MAINTENANCE AND OPERATING MANUAL HEF 005 240 38178800738 Original instructions...

Page 2: ......

Page 3: ...without notice Reproduction of this manual is strictly prohibited INDEX INDEX 1 INTRODUCTION 2 SAFETY 2 INTENDED USE 2 FILTRATION GRADES AND APPLICATIONS 3 INSTALLATION 4 1 1 Models HEF 005 070 4 1 2...

Page 4: ...FETY ATTENTION Absolutely avoid to place the filter in zones influenced by warm air flows or near flammable materials Avoid vibrations during filter operation they could cause damages Do not use the f...

Page 5: ...n to 0 1 micron liquid and oil included Maximum contents of residual oil 0 1 mg m3 Normally used as a prefilter at the entrance of the dryer with frigorific cycle to prevent deterioration of pipes in...

Page 6: ...nd and below them see minimum distance D in the technical data table so as to be able to disassemble the bowl and the cartridge as shown Stick the adhesive label showing the month and year for the nex...

Page 7: ...ine from the filter slowly open the on off valve V2 up line from the filter and let the air flow from the manual or automatic drain valve for a few minutes close the drain valve and open the on off va...

Page 8: ...kwise In this case automatic operation is overridden until the closed position is restored For the installation insert the automatic condensate discharger SCF into the casing and screw it onto the con...

Page 9: ...without notice Reproduction of this manual is strictly prohibited On Request 1 Condensate separator 2 Wall mounting kit 3 Serie connection kit 4 Differential pressure gauge 2 3 2 4 5 1 3 Vaselline To...

Page 10: ...ies from case to case It is recommended that the cartridge is replaced at least once a year but depending on the application this can be required every 6 months 1 Remove the bowl 2 HEF 094 240 Remove...

Page 11: ...1 HEF 175 21 2 1680 935 163 43 770 14 0 6 9 HEF 200 3 2160 795 240 59 630 20 0 12 9 HEF 240 3 2760 1000 240 59 780 24 40 14 0 Flow rate condition FAD 20 C 1 bar A operating pressure 7 barg air operati...

Page 12: ...nufacturer without notice Reproduction of this manual is strictly prohibited CORRECTION FACTORS Operating pressure bar 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Operating pressure psi 29 44 58 72 87 100 11...