background image

COMPRESSED AIR FILTER

MAINTENANCE AND OPERATING MANUAL

HEF 005÷240

38178800738

Original instructions

Summary of Contents for HEF 005

Page 1: ...COMPRESSED AIR FILTER MAINTENANCE AND OPERATING MANUAL HEF 005 240 38178800738 Original instructions...

Page 2: ......

Page 3: ...without notice Reproduction of this manual is strictly prohibited INDEX INDEX 1 INTRODUCTION 2 SAFETY 2 INTENDED USE 2 FILTRATION GRADES AND APPLICATIONS 3 INSTALLATION 4 1 1 Models HEF 005 070 4 1 2...

Page 4: ...FETY ATTENTION Absolutely avoid to place the filter in zones influenced by warm air flows or near flammable materials Avoid vibrations during filter operation they could cause damages Do not use the f...

Page 5: ...n to 0 1 micron liquid and oil included Maximum contents of residual oil 0 1 mg m3 Normally used as a prefilter at the entrance of the dryer with frigorific cycle to prevent deterioration of pipes in...

Page 6: ...nd and below them see minimum distance D in the technical data table so as to be able to disassemble the bowl and the cartridge as shown Stick the adhesive label showing the month and year for the nex...

Page 7: ...ine from the filter slowly open the on off valve V2 up line from the filter and let the air flow from the manual or automatic drain valve for a few minutes close the drain valve and open the on off va...

Page 8: ...kwise In this case automatic operation is overridden until the closed position is restored For the installation insert the automatic condensate discharger SCF into the casing and screw it onto the con...

Page 9: ...without notice Reproduction of this manual is strictly prohibited On Request 1 Condensate separator 2 Wall mounting kit 3 Serie connection kit 4 Differential pressure gauge 2 3 2 4 5 1 3 Vaselline To...

Page 10: ...ies from case to case It is recommended that the cartridge is replaced at least once a year but depending on the application this can be required every 6 months 1 Remove the bowl 2 HEF 094 240 Remove...

Page 11: ...1 HEF 175 21 2 1680 935 163 43 770 14 0 6 9 HEF 200 3 2160 795 240 59 630 20 0 12 9 HEF 240 3 2760 1000 240 59 780 24 40 14 0 Flow rate condition FAD 20 C 1 bar A operating pressure 7 barg air operati...