31
COMPRAG
Screw air compressor FV-Series
1
5.8
Cleaning radiator
In order to access the radiator (1),
open the front or left panel.
Regularly clean the radiator in order
to maintain its cooling efficiency at
an acceptable level.
Remove any dirt particles from the
radiator using a fibre brush, then aim
a jet of compressed air at the radiator
from the bottom to the top; the jet
should be held at an approximate 90°
angle to the plane of the radiator.
D2
motor shaft
(
mm
) х 0,005 = М
(lubricant mass)
(
g
).
Fig. 5.8 Cleaning radiator
5.9
Checking suction valve
In order to access the intake valve, the air filter has to be removed in accordance with
section 5.5.
Then open the air throttle by hand, ensuring that it has a smooth stroke and can be
opened fully. If the air throttle jams or doesn’t operate fully, then replace the valve with a new one.
5.10
Servicing bearings of electric motor
When the compressor is used, fresh viscous lubricant (formulated for rolling bears) should be
added to the motor’s bearings. Lubricant should be added using a special syringe for viscous
lubricants through lubricators accommodated in the motor’s bearing caps. The volume of lu-
bricant added can be calculated using the formula:
Do not over-lubricate the bearings beyond the standard level as all excess lubricant will be
squeezed out of the bearings into the motor when the motor is running.