24
Version 1.2
ERROR CODE
Description
Err.1
Over-current event during other conditions
Err.2
Over-current event during acceleration
Err.3
Over-current event during deceleration
Err.4
Over-current event while at constant speed
Err.5
Over voltage event during acceleration
Err.6
Over voltage event during deceleration
Err.7
Over voltage event while at constant speed
Err.8
Control circuit error
Err.9
Under-voltage error
Err.10
Inverter overload protection
Err.11
Motor overload protection
Err.12
Input phase loss protection
Err.13
Output phase loss protection
Err.14
Inverter thermal trip
Err.15
External trip
Err.16
Communications error ModBus
Err.18
Current detection error
Err.23
Ground fault
Err.40
Cyclic current excess
Err.51
Incorrect motor parameters
By any error in frequency inverter, a general error message VSD FAULT on the compressor control-
ler will be shown. When compressors stops and an error message VSD FAULT on the compressor
controller occurs- firstly reset fault on the inverter, secondary reset fault on the compressor con
-
troller. After both resets are done, start compressor again. If error reoccurs after reset, please
contact a professional service partner.
The last 5 error messages are retained in the memory.
Restarting operation without eliminating the cause of the fault is
not permitted!