If the compressor is anchored to the base on which it is installed, the tilt angle with respect to
the horizontal surface must not exceed 7°. Install the compressor in a facility where precip
-
itation cannot reach. Choose a facility for installing the compressor with a minimum level of
dust. Install the compressor at least 1,5 m from walls.
If multiple compressors are installed, there should be a 1,5 m minimum distance between
each compressor. There should be a 4 m safety distance from the area of the operated equip-
ment connected to the compressor. The facility in which the compressor is installed must be
fitted with a combined extract-and-input ventilation system.
The facility where the compressor is installed should be provided
with air inflow equivalent to
twice the compressor’s capacity.
The volume of extraction ventilation must not exceed 40% of the air inflow capacity of the input
ventilation in a facility where the compressor is installed and fitted with an extract- and input ven-
tilation system.
The compressor should not be installed in a facility where the temperature may drop below
+5°С.
In order to extract hot air flowing out the compressor, an air duct may be used that is up to 3 m in
length and with a cross section 20% larger than that of the air-outflow orifice from the
compressor’s
radiator. If an air duct longer than 3 m is used, additional duct fans should be used.
3.4
Connection to the compressed airline
Provide the throughput capacity of the compressed-air line in accordance with the perfor-
mance of the compressor. In order to FVoid damage associated with seal failure of the com-
pressed-air line, the compressor should be connected via a flexible hose. All components of
the compressed-air line must hFVe a working pressure no less than the
compressor’s
nominal
pressure. Use a pressure vessel with a capacity corresponding to the compressor’s perfor
-
mance and the compressed air consumer.
3.5
Connecting to power supply
The compressor is not supplied with a power cable. The cable size must be chosen to ensure
that the maximum voltage drop not exceed 5 % of the nominal voltage value. Cable length
must not exceed 25 m. Ambient temperature in the facility must not exceed
40°C.
The cable
must be sheathed with a fire retardant compound. An isolating switch must be fitted within
reach of the compressor to facilitate connection
and maintenance.
The compressor must be earthed and protected against short cir-
cuits in each phase, impermissible voltage fluctuation and phase
failure.
The power cable has to be fed into the compressor.
Summary of Contents for A7510
Page 62: ...7 800 777 83 75 www v p k ru A7510 Comprag Comprag...
Page 64: ...7 800 777 83 75 www v p k ru A7510 1 1 1 1 2...
Page 65: ...7 800 777 83 75 www v p k ru A7510 1 2 3 Comprag 4 5 6 1 3 1 2 3...
Page 66: ...7 800 777 83 75 www v p k ru A7510 4 5 6 7 8 9 10 11 12...
Page 67: ...7 800 777 83 75 www v p k ru A7510 1 4 1 2 3 4 5 6 90 A 7 8...
Page 68: ...7 800 777 83 75 www v p k ru A7510 1 5 1 2 3 4 5 6 7 8 1 3 9 9 10 10 11 12 13...
Page 69: ...7 800 777 83 75 www v p k ru A7510 14 15 16 17 18 19...
Page 72: ...7 800 777 83 75 www v p k ru A7510 2 4 2 3 4 5 3 6 8 13 6 16 6 15 14 13 14 2 5 2 5 3 4...
Page 73: ...7 800 777 83 75 www v p k ru A7510 i Log 6 1 2 1 3 2 5 7 3 6 3 2 5 100...
Page 77: ...7 800 777 83 75 www v p k ru A7510 3 3 3 3 A75 90 1 2 3 7 5 C 40 C 40 2 1 1500 1500...
Page 78: ...7 800 777 83 75 www v p k ru A7510 3 4 3 5 5 25 3 5 1 3 2...
Page 79: ...7 800 777 83 75 www v p k ru A7510 2 2 6 3 4 4 1 A30 A90 i LOG...
Page 80: ...7 800 777 83 75 www v p k ru A7510 4 1 1 i Log 4 1 1 4 1 2...
Page 82: ...7 800 777 83 75 www v p k ru A7510 H 0000H 0000H 0000H 0000H 1 0000H 0000H 5 60...
Page 87: ...7 800 777 83 75 www v p k ru A7510 4 2 4 3 10 LCD...
Page 88: ...7 800 777 83 75 www v p k ru A7510 5 5 1 TO 1 TO 2 TO 3 TO 2 500 2000 4000 6000 6000 2 3 2000...
Page 89: ...7 800 777 83 75 www v p k ru A7510 5 2 5 2 1 5 3 5 3...
Page 91: ...7 800 777 83 75 www v p k ru A7510 5 5 1 2 5 5 5 6 5 6 4 1 2 2 3 2 4 5 3 4...
Page 92: ...7 800 777 83 75 www v p k ru A7510 5 7 2 5 7 5 8 90 5 8...
Page 93: ...7 800 777 83 75 www v p k ru A7510 5 9 5 5 5 10 D2 0 005...
Page 94: ...7 800 777 83 75 www v p k ru A7510 6 6 1 5 3 5 3 5 40 5 2 5 8 13 13...
Page 95: ...7 800 777 83 75 www v p k ru A7510 7 7 1 20 35 85 7 2...