31
Compool Cp3830
Programming
Typically only the Pool and Spa keys (filtration) needs to be programmed. Other Equipment
keys can be programmed the same way.
•
To program Pool filtration
1.
Press the Program key.
2.
Press the Pool key.
3.
Press the Hours/Minutes key to
set the START TIME.
4.
Press the Enter key.
5.
Press the Hours/Minutes key to
set the RUN TIME.
6.
Press the Program key to end.
Programming additional Run Times
It is possible to program up to four separate START TIME and RUN TIME’s for each
equipment key. Follow the previous example to step 2, then press the same equipment key until
PROG 2 is displayed. Continue with steps 3-6 to enter the second START TIME and RUN
TIME.
Programming a Time-out
By default, manually activated equipment will Time-out after 12 hours. However, it is possible
to program a different Time-out period for each equipment key.
Follow Programming example, set START TIME to 0:00 hours. Set RUN TIME to the number
of Hour/Minutes before equipment should Time-out.