- Page 4 -
Up-Flow Furnace / Air Handler
The Complete Comfort™ Cabinet is installed horizontally
beneath the furnace / air handler. Return air enters from the
bottom (see figure 6).
APPLICATIONS
Down-Flow Furnace / Air Handler
The Complete Comfort™ Cabinet is installed horizontally in
the return air duct just above the furnace / air handler (see
figure 7).
Up-Flow Furnace (up to 4 ton application)
The Complete Comfort™ Cabinet is installed vertically and
return air enters the furnace side inlet (see figure 8).
Down-Flow Furnace / Air Handler
Option 1 - Install Return air base, part numbers 98M60,
98M58. Complete Comfort™ CCC20-28 Cabinet is installed
vertically and return air enters the furnace side inlet (see
figure 9).
Down-Flow Furnace / Air Handler
Option 2
-
Overcut top edge of side return opening by 1" to
15" x 23". Complete Comfort™ CCC20-28 Cabinet is installed
vertically and return air enters the furnace side inlet (see
figure 10).
Horizontal Furnace / Air Handler
The Complete Comfort™ Cabinet is installed vertically in the
return air duct near the furnace / air handler (see figure 8).
Figure 6. Up-flow Furnace / Air Handler
Figure 7. Down-flow Furnace / Air Handler
Figure 8. Up-flow Furnace (up to 4 ton)
Figure 9. Up-flow Furnace (5 ton, Option 1)
Figure 10. Up-flow Furnace (5 ton, Option 2)
Figure 11. Horizontal Furnace / Air Handler
SUPPLY
DUCT
RETURN
DUCT
SUPPLY
DUCT
RETURN
DUCT
RETURN
DUCT
SUPPLY
DUCT
SUPPLY
DUCT
RETURN
DUCT
OPTIONAL
RETURN
AIR BASE
OVERCUT TOP
EDGE BY 1"
15"
23"
SUPPLY
DUCT
RETURN
DUCT
506831-01
09/2011