Protective equipment
DC fault current monitoring (per-
sonal protection)
Integrated all-current sensitive current monitor (GFCI) for DC fault monitoring,
response value: DC 6 mA
Welding detection (indication signal
for welded power contacts)
Connection via change-over contact (max. 230 V, 1 A),
use e.g. for shunt release for disconnection of main power path
Integrated overvoltage protection
According to IEC 61851-21-2:2018 (ESD/surge/burst)
Communication
Vehicle communication
Charging current controlled via PWM pilot signal in accordance with IEC 61851-1:2017
Direct communication
Bluetooth Class 1 and 2 (power level)
Backend connectivity
Via OCPP 1.6J to Compleo backend or third-party backends
Backend communication
WLAN with 2.4 GHz IEEE 802.11 b/g/n with WPA2 (antenna gain, frequency-dependent, max. 4.6 dBi)
Authentication
Authentication
Free charging, smartphone app ( app/third-party apps) via contract charging
or direct payment via epowerdirect.com
16 | Specifications