Compcooler COMP-PCCU-24400S Operation Manual Download Page 4

 

Compcooler, keep your body cool and comfortable in harsh conditions. 

 

 

Chiller Unit Technical Datasheet 

 

Cooling Capacity (Ambient Temp. 40

400 

Cooling Capacity (Ambient Temp. 104

Btu 

1364 

Max Cooling Capacity  

600 

Power Supply  

V AC 

110 or 220 

V DC 

24-28V 

Operation Current 

12 

Max Current 

15 

Max Power Consumption   

400 

Refrigerant  

Type 

 

 

R134a 

Temp Control  

 

-5 to 30 

 

23-86 

Coolant  

Anti-freeze liquid  

 

 

Yes 

Rotary Compressor (S

am

sung) 

Qty 

PC 

Voltage 

V DC 

24 

Discharge 

CC 

2.4 

Speed 

RPM 

2000-6500 

Fan 

Qty 

PC 

Voltage 

V DC 

24 

Air Flow 

CFM 

45 

Pump 

Voltage 

V DC 

24 

Water flow 

L/Min 

Lift 

Power Connector  

Type 

AC

 

3 pins 

DC 

Aero Connector 

Operation Ambient  

Max 

 

-10 to 60 

Storage Temp 

 

 

 

-20 to 70 

Noise  

Max 

dBA 

58 

Color  

 

 

 

White or Black 

Dimension  

L x W x H 

mm 

356x200x217 

Inch 

14x7.9x8.5 

Weight 

KGS 

8.2 

LBS 

18 

 

 
 
 
 
 
 

Summary of Contents for COMP-PCCU-24400S

Page 1: ...Compcooler keep your body cool and comfortable in harsh conditions 1 Portable Chiller Cooling Unit Model COMP PCCU 24400S Rev A Operation Manual ...

Page 2: ...oyees at Compcooler s state of the art manufacturing facility have been producing liquid heating cooling systems over 15 years Quality system ISO9001 and AS9100 registered facility Certifications for major items CE FCC UL PSE CB FDA Product Categories 1 ICE Water Circulation Systems 2 Micro Refrigeration Chiller Units 3 Liquid Heating Systems 4 Liquid Cooling Heating Garment and Pad 5 Customized C...

Page 3: ...0W cooling capacity powered by 110 220V AC wall plug or 24V DC battery temp control 5 to 30 23 to 86 accuracy 1 2 once circulation liquid reaches to set point temperature system intellectually control the cooling capacity to that temperature User may pre cool the unit and get the coldest liquid as he needs iceless cooling unit maintain free This model is good for body cooling by connect with cooli...

Page 4: ...ower Consumption W 400 Refrigerant Type R134a Temp Control 5 to 30 23 86 Coolant Anti freeze liquid Yes Rotary Compressor Samsung Qty PC 1 Voltage V DC 24 Discharge CC 2 4 Speed RPM 2000 6500 Fan Qty PC 2 Voltage V DC 24 Air Flow CFM 45 Pump Voltage V DC 24 Water flow L Min 5 Lift M 5 Power Connector Type AC 3 pins DC Aero Connector Operation Ambient Max 10 to 60 Storage Temp 20 to 70 Noise Max dB...

Page 5: ...nt may be changed for different ambient Chiller Unit Performance Curves Operation ambient for chiller unit is 10 to 60 Cooling capacity could be difference based on ambient and liquid temp setting 0 2 4 6 8 10 12 14 0 20 40 60 80 100 Current of Chiller DC 24V Operation Time Seconds Compressor Start Curves 0 100 200 300 400 500 600 0 5 10 15 20 25 30 Cooling Capacity W Liquid Temperature Performanc...

Page 6: ... for fresh air inlet and outlet Power Connection AC Wall Plug One AC power cord was provided with chiller user may connect it with wall inlet plug 110V or 220V Please make sure the unit voltage 110V or 220V before operation DC Battery Connection One DC power cord with female aero connector was provided with chiller user may connect it with battery or vehicle power 24 28V DC Power Switch User need ...

Page 7: ...p from top side add liquid to full by funnel connect the cooling garment turn on the pump and circulates the liquid from reservoir to cooling garment The second time keep running and allow the liquid cooling garment fill with water for 30 60 seconds without cooling refill again to full maybe couple times be patient then tight the filler cap Clean or distilled water is fine if ambient more than 1 D...

Page 8: ... connection turn on power switch and light the front panel The cooling unit will be in standby mode 3 Start cooling user may press ON OFF to start chiller liquid temperature will go down to set point in minutes pump is not working at this time 4 Temp setting user may press up and down to set up the temp for circulation liquid as need 5 Start circulation User may press the pump to start or stop cir...

Page 9: ...as decreased because of lack of refrigerant user may vacuum the unit and recharge 150g R134a refrigerant Liquid Heating Cooling Pad or garment Machine wash wash liquid heating and cooling pad using a front loading wash machine with cold water on a gentle delicate cycle secure the connection tubes to minimize risk of it flailing in the spin cycle and damaging connector and tubing sewing Note DO NOT...

Page 10: ... unit could be overheated protection in hot ambient 9 Please stop operation and disconnect the power if high vibration or abnormal noise Safety It is important to become thoroughly familiar with the manual and operating characteristics of the unit It is the owner s responsibility to assure proper operator training installation operation and maintenance of the unit Observe all warning can result in...

Page 11: ...Compcooler keep your body cool and comfortable in harsh conditions 11 ...