Trouble shoot and Fault Code  

 

Item 

Code 

Description  

E1 

Wrong Polarity or reverse connection from power input 

E2 

Low voltage protection, less than 18V 

E3 

High voltage protection, more than 32V 

P1 

No liquid temp signal from sensor   

 

Cautions: 

1.

 

Please confirm chiller voltage is 110V or 220V before connect AC power. 

2.

 

Please make sure battery output 20A for DC operation, or 400W for vehicle operation. 

3.

 

Please do not turn ON/OFF to run to stops system frequently within a short period, it may 
affect the refrigeration system, and significant enhance power consumption. 

4.

 

Please do not block air inlet and outlet, it may cause the problem of compressor overheat or 
less cooling capacity. 

5.

 

Please make sure cooling garments or vest be connected before start pump circulation, it may 
cause unit leak because of pump pressure. 

6.

 

Please use anti-freeze liquid if temperature setting lower than 0

 

7.

 

Please do not run the system close to fire or under water. 

8.

 

Max operation temp is 60

, unit could be overheated protection in hot ambient. 

9.

 

Please stop operation and disconnect the power if high vibration or abnormal noise. 

 
 

Safety: 

It is important to become thoroughly familiar with the manual and operating characteristics of the 

unit. It is the owner’s responsibility to assure proper operator training, installation, operation and 

maintenance of the unit. Observe all warning can result in injury to the operator and severe 
mechanical damage to the unit. 

 

Warranty:  

Compcooler Warrants to the original Purchaser that products sold shall be free from defects 
material and workmanship for warranty period not exceed one year from the date of shipment. 
Compcooler agrees to correct for the original user of this product, either by repair, or at the 

manufacturer’s election by replacement. This warranty shall not apply if the defect or malfunction 

was caused by accident, neglect, unreasonable use, improper service, or other causes not arising 
out of defects in material or 

workmanship. The manufacturer’s sole obligation under this warranty 

is limited to the repair or replacement of a defective product and shall not in any event be liable 
for any incidental or consequential damages of any kind resulting from use or possession of this 
product. 
 
 
 
 

Summary of Contents for COMP-PCCU-24400S

Page 1: ...Compcooler keep your body cool and comfortable in harsh conditions 1 Portable Chiller Cooling Unit Model COMP PCCU 24400S Rev A Operation Manual ...

Page 2: ...oyees at Compcooler s state of the art manufacturing facility have been producing liquid heating cooling systems over 15 years Quality system ISO9001 and AS9100 registered facility Certifications for major items CE FCC UL PSE CB FDA Product Categories 1 ICE Water Circulation Systems 2 Micro Refrigeration Chiller Units 3 Liquid Heating Systems 4 Liquid Cooling Heating Garment and Pad 5 Customized C...

Page 3: ...0W cooling capacity powered by 110 220V AC wall plug or 24V DC battery temp control 5 to 30 23 to 86 accuracy 1 2 once circulation liquid reaches to set point temperature system intellectually control the cooling capacity to that temperature User may pre cool the unit and get the coldest liquid as he needs iceless cooling unit maintain free This model is good for body cooling by connect with cooli...

Page 4: ...ower Consumption W 400 Refrigerant Type R134a Temp Control 5 to 30 23 86 Coolant Anti freeze liquid Yes Rotary Compressor Samsung Qty PC 1 Voltage V DC 24 Discharge CC 2 4 Speed RPM 2000 6500 Fan Qty PC 2 Voltage V DC 24 Air Flow CFM 45 Pump Voltage V DC 24 Water flow L Min 5 Lift M 5 Power Connector Type AC 3 pins DC Aero Connector Operation Ambient Max 10 to 60 Storage Temp 20 to 70 Noise Max dB...

Page 5: ...nt may be changed for different ambient Chiller Unit Performance Curves Operation ambient for chiller unit is 10 to 60 Cooling capacity could be difference based on ambient and liquid temp setting 0 2 4 6 8 10 12 14 0 20 40 60 80 100 Current of Chiller DC 24V Operation Time Seconds Compressor Start Curves 0 100 200 300 400 500 600 0 5 10 15 20 25 30 Cooling Capacity W Liquid Temperature Performanc...

Page 6: ... for fresh air inlet and outlet Power Connection AC Wall Plug One AC power cord was provided with chiller user may connect it with wall inlet plug 110V or 220V Please make sure the unit voltage 110V or 220V before operation DC Battery Connection One DC power cord with female aero connector was provided with chiller user may connect it with battery or vehicle power 24 28V DC Power Switch User need ...

Page 7: ...p from top side add liquid to full by funnel connect the cooling garment turn on the pump and circulates the liquid from reservoir to cooling garment The second time keep running and allow the liquid cooling garment fill with water for 30 60 seconds without cooling refill again to full maybe couple times be patient then tight the filler cap Clean or distilled water is fine if ambient more than 1 D...

Page 8: ... connection turn on power switch and light the front panel The cooling unit will be in standby mode 3 Start cooling user may press ON OFF to start chiller liquid temperature will go down to set point in minutes pump is not working at this time 4 Temp setting user may press up and down to set up the temp for circulation liquid as need 5 Start circulation User may press the pump to start or stop cir...

Page 9: ...as decreased because of lack of refrigerant user may vacuum the unit and recharge 150g R134a refrigerant Liquid Heating Cooling Pad or garment Machine wash wash liquid heating and cooling pad using a front loading wash machine with cold water on a gentle delicate cycle secure the connection tubes to minimize risk of it flailing in the spin cycle and damaging connector and tubing sewing Note DO NOT...

Page 10: ... unit could be overheated protection in hot ambient 9 Please stop operation and disconnect the power if high vibration or abnormal noise Safety It is important to become thoroughly familiar with the manual and operating characteristics of the unit It is the owner s responsibility to assure proper operator training installation operation and maintenance of the unit Observe all warning can result in...

Page 11: ...Compcooler keep your body cool and comfortable in harsh conditions 11 ...

Reviews: