The 42U modular storage cabinet supports the following configurations:

NOTE:

  The following lists what the maximum number of each component that can be

installed in a 42U cabinet. The total number of components that will physically fit into the

42U cabinet is limited by the amount of space. See Table 2 for individual component

height.

 

No more than three Model 2200 controller enclosure shelves (each
controller enclosure can contain a maximum of two HSG80 controllers)
(DS-SE2ZS-C8 / 135820-B21)

 

No more than nine Model 4214R disk enclosure shelves
(DS-SSL14-RS / 103381-001)
or nine Model 4254 disk enclosure shelves
(DS-SSL14-RM / 103381-001)

 

No more than two Compaq StorageWorks SAN Switch 8
(DS-DSGGB-AA / 158222-B21)

 

No more than two Compaq StorageWorks SAN Switch 16
(DS-DSGGB-AB / 158223-B21)

 

No more than seven Fibre Channel Hub, 7-port
(DS-SWXHB-07 / 234453-001)
(DS-SWXHB-I7 / 234453-B31)
(DS-SWXHB-J7 / 234453-291)

 

No more than two Fibre Channel Hub, 12-port
(DS-GHGGB-AA / 295573-B22)

Summary of Contents for StorageWorks 9000 22U

Page 1: ...ject Modular Array Configuration Guide Comments Part Number EK MACON CA A01 File Name EK MACON CA A01 doc Last Saved On 4 3 00 3 52 PM Compaq StorageWorks Modular Array Configuration Guide First Editi...

Page 2: ...WARRANTY OF ANY KIND THE ENTIRE RISK ARISING OUT OF THE USE OF THIS INFORMATION REMAINS WITH RECIPIENT IN NO EVENT SHALL COMPAQ BE LIABLE FOR ANY DIRECT CONSEQUENTIAL INCIDENTAL SPECIAL PUNITIVE OR OT...

Page 3: ...s on Equipment vi Rack Stability vii Getting Help vii Compaq Technical Support vii Compaq Website viii Compaq Authorized Reseller viii Modular Array Configuration Guide Introduction 1 Single Bus Mode...

Page 4: ...mpaq Confidential Need to Know Required Writer Patrick Waychoff Project Modular Array Configuration Guide Comments Part Number EK MACON CA A01 File Name EK MACON CA A01 doc Last Saved On 4 3 00 3 52 P...

Page 5: ...Keys appear in boldface A plus sign between two keys indicates that they should be pressed simultaneously USER INPUT User input appears in a different typeface and in uppercase FILENAMES File names ap...

Page 6: ...mation IMPORTANT Text set off in this manner presents clarifying information or specific instructions NOTE Text set off in this manner presents commentary sidelights or interesting points of informati...

Page 7: ...ely disconnect power from the system Rack Stability WARNING To reduce the risk of personal injury or damage to the equipment be sure that The leveling jacks are extended to the floor The full weight o...

Page 8: ...www compaq com Be sure to have the following information available before you call Compaq Technical support registration number if applicable Product serial number s Product model name s and numbers...

Page 9: ...U 36U and 22U The top gun blue RETMA cabinet is available in a 41U height Single Bus Mode or Dual Bus Mode The HSG80 controller firmware ACS 8 5 can address up to 12 drives per UltraSCSI bus In single...

Page 10: ...r channel can degrade performance Doubles rack space consumed versus dual bus shelves Dual Bus Fewer drives per channel may increase performance Half the rack space consumed versus single bus shelves...

Page 11: ...hows an example of the cabinets Figure 1 Example of the 42U 36U and 22U cabinets Table 2 lists the height of the various components that can be installed in the cabinets Table 2 Component Height Compo...

Page 12: ...ically when more than three disk enclosures are used the first three would be installed under the Model 2200 controller enclosure the next three would be installed on top of the controller enclosure s...

Page 13: ...el 4214R disk enclosure is configured in this manner only three of the I O ports are being used Figure 3 Examples of modular building blocks using either the Model 4214R single bus or Model 4254 dual...

Page 14: ...it into the 41U cabinet is limited by the amount of space See Table 2 for individual component height No more than two Model 2200 controller enclosure shelves each controller enclosure can contain a m...

Page 15: ...into the 42U cabinet is limited by the amount of space See Table 2 for individual component height No more than three Model 2200 controller enclosure shelves each controller enclosure can contain a m...

Page 16: ...it into the 36U cabinet is limited by the amount of space See Table 2 for individual component height No more than two Model 2200 controller enclosure shelves each controller enclosure can contain a m...

Page 17: ...it into the 22U cabinet is limited by the amount of space See Table 2 for individual component height No more than two Model 2200 controller enclosure shelves each controller enclosure can contain a m...

Page 18: ...mpaq Confidential Need to Know Required Writer Patrick Waychoff Project Modular Array Configuration Guide Comments Part Number EK MACON CA A01 File Name EK MACON CA A01 doc Last Saved On 4 3 00 3 52 P...

Reviews: