![Compaq Storageworks SAN Switch 16 Installation And Hardware Manual Download Page 60](http://html1.mh-extra.com/html/compaq-storageworks/san-switch-16/san-switch-16_installation-and-hardware-manual_2646670060.webp)
6-2
Compaq StorageWorks SAN Switch 16 Installation and Hardware Guide
Compaq Confidential – Need to Know Required
Writer: Hilary Stead Project: Compaq StorageWorks SAN Switch 16 Installation and Hardware Guide Comments:
Part Number: EK-BCP28-IA / 161356-001 File Name: G-CH6 ERROR MESSAGES.DOC Last Saved On: 9/30/99 11:32 AM
■
4—Informational
■
5—Debug
To display error messages using the front panel controls:
1.
Select the Status menu from the front panel controls.
2.
Select Error Log.
3.
Scroll through the error log. If no errors are encountered, the front panel
displays “No Error.”
Telnet Format
During a Telnet session, use the
errShow
command to display all detected
errors. The error counter goes to a maximum of 999. The following
information displays for each detected error:
■
Number of errors detected
■
Task ID and task name (task names are displayed using the
i
command)
■
Error type, date and time, error level, and description
■
Number of occurrences (shown in brackets following the date and time
stamp)
The error message display pauses after each error and prompts you to press
Enter to continue or Q to quit. Continue pressing Enter until the prompt
=>
displays. Only diagnostic errors are assigned error numbers. If no errors
encountered, the message “No Error” displays.
To display error messages through Telnet:
1.
At the prompt, enter
errShow.
2.
Type
<CR>
to scroll through the error list.