background image

3

12V PORTABLE CAMP SHOWER

OPERATING INSTRUCTIONS

•  Use clean water, do not use direct from river or lakes.

•  Do not operate shower without water at any time.

•  Ensure bucket is filled with sufficient water for 

intended use.

Step 1.

 Insert rubber washer in hose connection and 

connect hose to shower head.

Step 2.

 Place shower pump in bucket.

Step 3.

 Insert cigarette lighter into suitable 12V DC 

outlet and switch on inline switch.

Step 4.

 Adjust flow of water as required using control on 

shower head.

IMPORTANT

Do not take the pump out of the bucket while in use  

and ensure it is submerged in water before use.

TROUBLE SHOOTING

IF WATER DOES NOT FLOW

•  Turn off pump.

•  Lift pump from bucket and hold shower head 

vertical to draw water from shower.

•  Place pump in bucket and retry.

IF PUMP DOES NOT RUN

•  Check sufficient 12V DC power is available.

•  Check fuse in cigarette lighter fitting.

SPECIFICATIONS

Part no.

PCS12V

Water flow

4 L per minute

Power supply

12V DC

Power cord length

4 m

Hose length

2 m

Fuse

5A

Max. draw

3A

Weight

0.68 kg

Reviews: