App 408 Customer PET controller installation guide & user's manual
Page 11
98155.1015
App 408C
2.2.7 Factory
settings
In the factory menu, the following fundamental parameters can be set:
Parameter
Function
Default
Min.
Max.
DEF fault
delay
The time that a fault on the digital inputs D,E or
F are overridden before the compressor is shut
down.
15s
1s
60s
Oil pressure
The minimum oil pressure limit on which the
compressor is shut down. This is overridden by
oil pressure delay on start up
1 bar
0.3bar
2bar
Oil Pressure
delay
The time that the low oil pressure trip limit is
overridden on start up after the star start.
10 s
1s
30s
1
st
stage high
pressure
The high pressure limit for the 1
st
stage on which
the compressor is shut down. A warning will be
indicated at 0.2 bar below this pressure.
4.1 bar
***
1
st
stage
low
press
6 bar
1
st
stage low
pressure
The low pressure limit for the 1
st
stage on which
the compressor is shut down. This pressure is
overridden if the 3
rd
stage pressure is below its
low limit. A warning will be indicated at 0.2 bar
above this pressure.
2.5 bar
***
0
1
st
stage
high
press
2
nd
stage high
pressure
The high pressure limit for the 2
nd
stage on
which the compressor is shut down. A warning
will be indicated at 0.4 bar below this pressure.
15 bar
***
0
16 bar
3
rd
stage high
pressure
The high pressure limit for the 3
rd
stage on which
the compressor is shut down.
44 bar
***
0
50 bar
3
rd
stage low
pressure
The low pressure limit for the 3
rd
stage. This is
used to override the 1
st
stage low pressure trip.
15 bar
***
0
3
rd
stage
high
press
Pressure delay
fault
The time that the stage pressure faults are
overridden before they stop the compressor.
10 s
1s
30s
Stage 1 high
temperature
The temperature limit for the 1
st
stage on which
the compressor is shut down. A warning will be
indicated at 10°C below this temperature.
200°C
***
50
230
Stage 2 high
temperature
The temperature limit for the 2
nd
stage on which
the compressor is shut down. A warning will be
indicated at 10°C below this temperature.
200°C
***
50
220
Stage 3 high
temperature
The temperature limit for the 3
rd
stage on which
the compressor is shut down. A warning will be
indicated at 10°C below this temperature.
200°C
***
50
220
Final delivery
air temperature
The temperature limit for the final delivered air
on which the compressor is shut down. A
warning will be indicated at 5°C below this
temperature.
50°C
***
20
70
Water
temperature
The temperature limit for the cooling water
through the cylinders on which the compressor
is shut down. A warning will be indicated at 5°C
below this temperature.
60°C
***
20
70
P. max
The pressure limit at which the machine unload
pressure can be set.
42.1Bar
***
20 bar
3
rd
stage
high
pressure
Summary of Contents for 5280D.1.IAC
Page 3: ...DATE REMARKS DATE REMARKS logsheet5280 d...
Page 9: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 6 1440 doc...
Page 29: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 26 1440 doc...
Page 33: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 30 1440 doc...
Page 39: ......
Page 40: ......
Page 41: ......
Page 42: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 36 1440 doc...
Page 44: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 38 1440 doc CRANKCASE 1...
Page 46: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 40 1440 doc CRANKCASE 2...
Page 48: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 42 1440 doc CRANKCASE 3...
Page 50: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 44 1440 doc CYLINDER 1st STAGE...
Page 52: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 46 1440 doc SUCTION VALVE COVER...
Page 60: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 54 1440 doc CROSSHEAD 1st STAGE...
Page 62: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 56 1440 doc PISTON 1st STAGE...
Page 64: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 58 1440 doc GLAND 1st STAGE...
Page 66: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 60 1440 doc OIL PUMP...
Page 68: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 62 1440 doc OIL PUMP FILTER...
Page 70: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 64 1440 doc INTERCOOLER...
Page 72: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 66 1440 doc 1st STAGE PIPE WORK...
Page 74: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 68 1440 doc...
Page 76: ......
Page 77: ......
Page 78: ......
Page 79: ......
Page 80: ......
Page 81: ......
Page 82: ......
Page 83: ......
Page 84: ......
Page 85: ......
Page 86: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 70 1440 doc...
Page 94: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 72 1440 doc...
Page 98: ...App 408 Customer PET controller installation guide user s manual Page 2 App 408C 98155 1015...
Page 120: ...CompAir UK Ltd APP 004 ANTI VIBRATION MOUNTS Page 2 app004 doc...
Page 122: ...CompAir UK Ltd PUBLICATION APP070 PRESSURE GAUGES GENERAL Page 2 app070 doc...
Page 128: ...CompAir UK Ltd PUBLICATION APP 138 3 WAY SOLENOID VALVES PS2197 Page 2 app138 doc...
Page 130: ...CompAir UK PUBLICATION APP034 ELECTRIC MOTOR MAINTENANCE GENERAL Page 2 APP034 doc...
Page 133: ...CompAir UK Ltd 5280D Compressor Publication 98407 1440 Page 74 1440 doc...