background image

Page 9

SB-2-546

NIOSH-Certified for respiratory protection in 
atmospheres not immediately dangerous to life.

Consists of :

1 - Piercing Tool, 

48 - Disposable Liners, 48 - Drain Bushings

OMX-70-K48 Paint Cup Liner Kit 

Allows quick & easy clean-up.

(1) Wall mount bracket 
included with GH-407. 
Holds standard paint
cups, gravity feed guns and
cups, and paint filters.

GH-407 

Gun Holder

Gun holders are
made to hold stan-
dard paint cups, grav-
ity feed guns and
cups, and paint filters.

GH-505 

Gun Holder

Cleaning Brushes

42884-214-K5 (3/8")

42884-215-K10 (5/8")

These brushes are
helpful in cleaning
threads and recesses
of gun body.

Compatible with all paint materials;
contains no silicone or petroleum
distillates to contaminate paint.
MSDS  Sheet available upon request.

Contains all neces-
sary tip, hose and
nut sizes used on or
with gun.

SPN-5 Wrench

Scrubs®

are a pre-

moistened hand cleaner
towel for painters, body
men and mechanics that
go where you go and no
water is needed.

29-3100-K6 Scrubs®

Hand Cleaner Towels

HC-4700

1/4" NPT(F)

HC-1166

1/4" NPT(M)

HC-4699

1/4" NPT(M)

HC-4419 

1/4" NPS(F)

Industrial Quick Connects 

for HVLP Guns (Air)

Spray Gun Lube 

SSL-10-K12 (2 oz. bottle)

Fits Compact gun only. 

Compatible with DeVilbiss

high flow quick disconnects.

MPV-60-K3

Air Inlet Swivel

(Pack of 3)

Installs into gun to enable

user to control and reduce

air usage at the gun.

Replaces SP-637 plug.

SP-402-K

Air Adjusting Valve

Paint Spray Respirators

40-141 (Sm)   40-128 (Med)   40-143 (Lg)

ACCESSORIES

These gravity feed cups
are designed to be used
with EXL, FLG, GFG, 
GFHV, GTI or Compact
gravity feed spray guns.

DGI-501-PSI-USA

Digital 

Pressure Gauge

Digital pressure
gauge for precise
pressure control at
the gun.

GFC-501 (Acetal) 20 Oz. Cup

GFC-502 (Aluminum) 1-Liter Cup

Gravity Feed Cups

HAV-500 does not
have pressure gauge.
Use to control air 
usage at gun.

HAV-500 OR

HAV-501

Adjusting Valve

(HAV-501 SHOWN)

Summary of Contents for COM-G430-14-02

Page 1: ...in SB 2 546 OPERATION MANUAL ADVANCED CONVENTIONAL GRAVITY FEED SPRAYGUN English Pages 2 9 MANUAL DE OPERACI N COMPACT PISTOLA PULVERIZADORA CONVENCIONAL AVANZADO CON ALIMENTACI N POR GRAVEDAD Espa ol...

Page 2: ...logenated Hydrocarbons Static Electricity can be generated by fluid and or air passing through hoses by the spraying process and by cleaning non conductive parts with cloths To prevent ignition source...

Page 3: ...5 Spreader Valve SP 403 K 1 6 Stud and Screw GTI 408 K5 5 7 Needle Adjusting Screw SP 614 K 1 8 Spring SP 622 K5 1 9 Needle SP 300S K 1 14 18 22 e g 14 1 4 mm 10 Airvalve housing seal SP 612 K 1 11 Sp...

Page 4: ...Overlap each stroke a minimum of 50 Move gun at a constant speed 14 Always turn off air supply and relieve pressure when gun is not in use PREVENTATIVE MAINTENANCE 1 Turn off air and relieve pressure...

Page 5: ...Service Tool SPN 7 engage groove behind the Valve Seat 6 Remove Valve Seat 7 Push out the Front Airvalve Seal with a finger 8 Turn the Gun upside down and let the Seal fall out 9 Fit New Front Seal t...

Page 6: ...ent 14 Fit new Seal to Service Tool 15 Fit Seal to Housing 10 16 Replace Valve 11 17 Replace Valve Spring and screw in Housing 10 18 Tighten Housing 19 Fit Needle 9 20 Fit Spring 8 and Knob 7 21 Adjus...

Page 7: ...om work surface Gun motion too fast Gun out of adjustment Packing nut loose Packing worn or dry Packing nut too tight Dry packing Fluid tip or needle worn or damaged Foreign matter in tip Fluid needle...

Page 8: ...paint manufacturer s mixing instrs Properly clean and prepare Cup loose on gun Cup gasket worn or missing below cup Cup threads dirty Too much material flow Material too thin Gun tilted on an angle or...

Page 9: ...s are a pre moistened hand cleaner towel for painters body men and mechanics that go where you go and no water is needed 29 3100 K6 Scrubs Hand Cleaner Towels HC 4700 1 4 NPT F HC 1166 1 4 NPT M HC 46...

Page 10: ...nerada por el paso de fluido y o aire por los manguitos por el proceso de pulverizaci n y por la limpieza de piezas no conductoras con pa os Para impedir que las descargas est ticas produzcan fuentes...

Page 11: ...403 K 1 6 Espiga y tornillo GTI 408 K5 5 7 Tornillo de ajuste de la aguja SP 614 K 1 8 Muelle SP 622 K5 1 9 Aguja SP 300S K 1 14 18 22 ej 14 1 4 mm 10 Alojamiento de la v lvula de aire SP 612 K 1 jun...

Page 12: ...ecomendada es de 150 200 mm 13 Pulverice primero los bordes Solape cada pasada el 50 como m nimo Mueva la pistola a una velocidad constante 14 Cierre siempre el suministro de aire y alivie la presi n...

Page 13: ...de la v lvula 6 Retire el asiento de la v lvula 7 Haga salir la junta delantera de la v lvula de aire empu jando con el dedo 8 Ponga la pistola boca abajo y deje que se caiga la junta 9 Instale una j...

Page 14: ...ta de manten imiento 15 Coloque la junta en el alojamiento 10 16 Vuelva a colocar el husillo 11 17 Vuelva a colocar el muelle de la v lvula y el tornillo en el alojamiento 10 18 Apriete el alojamiento...

Page 15: ...r pido Pistola desajustada Tuerca de la empaquetadura floja Empaquetadura gastada o seca Tuerca de la empaquetadura muy apretada Empaquetadura seca Punta de fluido o aguja gastada o da ada Materias fo...

Page 16: ...ante de la pintura Limpie y prepare debidamente Cubeta floja en la pistola Guarnici n de la cubeta gastada o falta debajo de la cubeta Roscas de la cubeta sucias Demasiado flujo de material Material d...

Page 17: ...Scrubs son toallas prehumedecidas para que pintores encargados de carrocer a y mec nicos se limpien las manos Van donde usted vaya y no se necesita agua 29 3100 K6 Scrubs Toallas para limpiarse las m...

Page 18: ...Page 18 SB 2 546 NOTES...

Page 19: ...P gina 19 SB 2 546 NOTAS...

Page 20: ...S Canada Technical Service Office 195 Internationale Blvd Glendale Heights IL 60139 Toll Free Telephone 1 888 992 4657 U S A and Canada only Toll Free Fax 1 800 368 8401 DeVilbiss Worldwide Sales and...

Reviews: