background image

 

2

/

8

 

A10 Userinstruction (EN).docx

 

 

2019-07-10 R1 S5 

Preface: 

Thank you for choosing a Compac product. 

 

Warranty: 

A 1-year warranty is furnished with the product, 
provided that the product is handled in accordance with the directions below. 
Note: Do not undertake constructive changes.

 

 
Cautions

 - safety measures  

1. 

The jack must only be used by trained personnel who have read and understood this manual. 

 

2. 

Avoid overloading. The capacity must not be exceeded.  

3. 

The jack must only be used on a horizontal, level and structurally stable substrate.  

4. 

The vehicle's wheels must be pointed forward, and braked or blocked.  

5. 

The jack is solely a lifting tool. Always support the vehicle with approved jack stands before working underneath the vehicle.  

6. 

Lift only at the vehicle's lifting points as prescribed by the manufacturer, and only centrally on the saddle.  

7. 

Being in, on or under a vehicle that is lifted or solely supported by a jack is forbidden.  

8. 

The jack may be used with a maximum of 1 standard extension piece delivered with the product.  

9. 

The jack - including the pressure relief valve - must not be modified.  

10. 

Maximum allowable air pressure: 10 bar/145 psi, minimum 300l/min.  

11

. Min. distance to walls min. 0.5m wrt/ emergency escape routes. 

12. 

Lacking compliance with these warnings can cause the load to fall down or the jack to malfunction, which may result in 

personal injuries or material damage. 
The jack must only be used from -5° to + 40° 
 

Mounting: See page 3

 

For mounting of joystick, see 

picture (1-6).

  

IMPORTANT: 

The hoses must go through the eye at the pull handle head, large hose at the bottom and small hose at the top 

(see picture 4).  

CAUTION:

 

Before placement into service and subsequently at periodic intervals, lubricate all movable parts with oil. Air connect

ion: 1/8”RG 

(see picture 7). Full capacity is achieved from 8 bar. Maximum air pressure :10 bar/145 psi. 

 
Operating manual:

 

Transport 

Transport and store the jack standing on its wheels. 

The handle 

can be set in 3 different positions (see picture 8-10) by turning the handle counterclockwise and tilting it up or down 

to the desired position.  

Raising: 

Press on the operating valve at the top of the handle (see picture 11), the pump will start and the jack will raise the 

load. 

Lowering: 

Pull the handle up and turn it clockwise (see picture 12.13). 

 
Maintenance: 

Maintenance and repairs must be performed by qualified personnel. 
As with all other pneumatic tools, the air motor requires oil for lubrication of moving parts. It is of special significance that, at 
periodic intervals, the moveable parts around the lifting arm be lubricated, by lubricating via the 5 lubrication nipples (see points 
on picture 20 and 21). It is recommended that an air supply be used with a filer/water trap and oil lubrication mechanism. 

Monthly: 

Empty the air supply's water trap and fill the lubrication mechanism up with oil. Lubricate all movable parts with oil. 

Remember lubrication via the 5 nipples in lifting arm (picture 20 and 21). At the same time, check jacks and extension pieces for 
damage and abnormal wear. For obvious wear of moving parts, replace them at an authorized workshop with original spare 
parts. 

Annually: 

Replace filter (see picture 14,17,18) 

Check the safety valve by pulling in the eye or air to whistle out of the valve 2-3 times (see picture19) 

Oil filling: 

Fill up with oil (see picture 14-16). The correct oil level is 10 mm below the top edge of the hole, when the jack is 

standing horizontally and the lifting arm is completely down.  

Oil quantity: 

A1,6+A2 = 0.4 l; A4 =1.0l; A10 = 1.2l. 

Oil type: 

Hydraulic oil with viscosity ISO VG 15, for example Castrol Hyspin AWS 15, Mobil DTE 10 Excel 15 or the equivalent. 

 

Never use brake fluid!

 

 
Safety inspection:

 

Summary of Contents for A10T-C

Page 1: ...9 07 10 R1 S5 User guide instructions for Compac air operated workshop jack A10T C 10 000 kg This user guide instructions is also available upon request in other languages at no charge Before using th...

Page 2: ...oil Air connection 1 8 RG see picture 7 Full capacity is achieved from 8 bar Maximum air pressure 10 bar 145 psi Operating manual Transport Transport and store the jack standing on its wheels The han...

Page 3: ...otor is running slowly or halts The air pressure from outside is not sufficient check the air supply 3 The load is dropping check for leaks Introduce press ball with mandrel only authorized personnel...

Page 4: ...Userinstruction EN docx 2019 07 10 R1 S5 Now ready for use Change the pull handle s position 3 positions Raise and lower the jack Raise the load Lower the load Press Lift Turn right 8 a 9 b 10 11 12...

Page 5: ...5 8 A10 Userinstruction EN docx 2019 07 10 R1 S5 Oil filling filter replacement check safety valve Greasing 14 16 15 17 18 19 20 21...

Page 6: ...instruction EN docx 2019 07 10 R1 S5 Signs Type Read manual Warning Do not side load saddle correct load on saddle Change pull handle position turn counter clockwise Lower the load 1 lift handle 2 tur...

Page 7: ...07 10 R1 S5 Pneumatic hydraulic diagram 1 Air pump 2 Safety valve 3 Valve 4 Exhaust filter 5 Press ball 6 Relief brake valve 7 Cylinder 8 Relief valve 9 Pressure regulator 10 Suction ball 11 Suction...

Page 8: ...nt shipping damage or any other cause not resulting from defective materials or workmanship Functional problems without any leakage like jack losing height unable to lift load etc are often due to imp...